PERANCANGAN SISTEM SCADA PENGENDALIAN SAND FILTER PADA AUTOMASI SISTEM PENGOLAHAN AIR BERBASIS PLC
Pengarang
Afiszan Ghifari - Personal Name;
Dosen Pembimbing
Fahri Heltha - 196309161990021001 - Dosen Pembimbing I
Roslidar - 197807192002122002 - Dosen Pembimbing II
Suriadi - 197206061998021001 - Penguji
Agus Adria - 196308131990021003 - Penguji
Fitri Arnia - 197311121999032001 - Penguji
Nomor Pokok Mahasiswa
1504105010020
Fakultas & Prodi
Fakultas Teknik / Teknik Elektro (S1) / PDDIKTI : 20201
Penerbit
Banda Aceh : Fakultas Teknik., 2021
Bahasa
Indonesia
No Classification
628.164
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Filtrasi merupakan salah satu proses penting dalam pengolahan air bersih di Perusahaan Daerah Air Minum (PDAM). Pada kasus yang diteliti, filtrasi menggunakan media pasir dengan sistem gravitasi lebih dikenal sebagai sistem filtrasi sand filter. Untuk menjaga performa filtrasi tetap dalam keadaan baik maka perlu dilakukan proses pencucian filternya (backwash) secara reguler. Saat filter telah mencapai kondisi jenuh atau kotor, maka debit filtrasi air akan melambat dan akan mempengaruhi debit produksi air bersih. Pada PDAM Tirta Daroy, pengecekan kondisi filter dan waktu pencucian masih dilakukan secara manual berdasarkan pengamatan dari operator secara langsung. Sehingga proses pencuciannya sangat tidak konsisten, tidak adaptif dan tidak efisien karena bergantung kepada kinerja operator. Dalam hal ini perlu adanya suatu sistem pengamatan dan kendali otomatis terpusat yang lebih konsisten, adaptif, dan efisien berbasis sensor, yaitu sistem SCADA yang terintegrasi dengan sistem kendali PLC. Platform SCADA Haiwell dikaji dan dirancang untuk dapat terintegrasi dengan PLC Outseal nano sehingga dapat menerima dan memaparkan berbagai format data dari PLC Outseal Nano kepada SCADA Haiwell dan demikian sebaliknya. Platform juga dirancang agar dapat menghasilkan tampilan interface yang ramah operator. Perancangan sistem SCADA difokuskan untuk meningkatnya efisiensi proses filtrasi bak sand filter serta efisiensi monitoring dan pengontrolan sistem sand filter. Pengujian sistem SCADA menghasilkan 100% kesesuaian pembacaan dan perekaman data, baik dari PLC Outseal ke SCADA Haiwell ataupun sebaliknya. Proses pengontrolan dan pengiriman data indikator dari SCADA ke PLC menghasilkan delay maksimal 1 detik. Hal ini terjadi karena adanya waktu interval refresh rate pada tampilan data SCADA Haiwell namun masih tetap merespon sesuai yang diharapkan. Proses koneksi tampilan SCADA dan sistem sand filter dapat terhubung dengan baik tanpa kendala serta tidak ada peringatan “device is not online”.
Filtration is one of the most important processes in the water treatment plant of PDAM to produce clean water. In this study, the filtration process uses sand as the filter media combined with a gravity system. To maintain a good filtration process, it is necessary to wash the filter (backwash filter) regularly when the filter’s condition has saturated or dirty, that causes slowing-down the flow of water filtration, and at the end, will causes decreament in the amount of clean water production. At PDAM Tirta Daroy, the investigation and monitoring of the filter condition, and its washing process are still conducted manually based on direct observation by of the operator. In this case, we proposed a centralized automatic observation, monitoring, and control system based on sensors feedback, known as SCADA system to integrate and manage all parts of the filtration system via a PLC control system. The platform of Haiwell SCADA system is reviewed and designed to be integrated with Outseal Nano PLCs, those should be able to receive and display various data formats from Outseal Nano PLC and vice versa, and be an operator-friendly interface display. The SCADA system is designed to increase the efficiency and variation modes of the monitoring and control process of the sand filter system. The SCADA system testing results shown 100% conformity of data reading and recording, whether from PLC to SCADA or vice versa, even there is a maximum delay of 1 second happen in the process of controlling and sending indicator data from SCADA to PLC. The delay is due to the refresh process time on the Haiwell's SCADA data display, it is still aceptable as the expected responds. The communications set-up between the SCADA system and the sand filter system as the plant has run smoothly without any constraints and errors, no warning errors appeared i.e. "device is not online” or not connected".
PERANCANGAN SISTEM KENDALI SAND FILTER BERBASIS PLC PADA INSTALASI PENGOLAHAN AIR (IPA) STUDI KASUS DI PDAM LAMBARO (Helda Sari, 2022)
AUTOMASI SISTEM DISTRIBUSI 20 KV DENGAN METODE FDISR (FAULT DETECTION, ISOLATION, SCANNING AND RESTORATION) PADA PENYULANG SUBSISTEM BANDA ACEH (KHAIRUL LINGGA, 2020)
PEMELIHARAAN SCADA PADA SISTEM PENGATUR DISTRIBUSI UP2D ACEH (Muhammad Rezeqi Tasrina, 2025)
PERANCANGAN SISTEM SCADA TERINTEGRASI IOT UNTUK DISTRIBUSI AIR DI BANDARA SULTAN ISKANDAR MUDA MENGGUNAKAN PROTOKOL MODBUS DAN MQTT (SUCI RAMADHANI, 2025)
RANCANG BANGUN PROTOTIPE SISTEM SCADA UNTUK OTOMATISASI POMPA DISTRIBUSI AIR PERUSAHAAN UMUM DAERAH AIR MINUM TIRTA DAROY (Ahmad Nawawi, 2024)