REMAINING LIFE ASSESMENT DAN RISK BASE INSPECTION PADA EQUIPMENT MAIN HEAT EXCHANGER DENGAN NOMOR ITEM E-101
Pengarang
WAN MUHAMMAD HAFIDH - Personal Name;
Dosen Pembimbing
19570627 198503 1 001/Prof. Dr. Ir. Nurdin Ali, Dipl. Ing - - - Dosen Pembimbing I
Syarizal Fonna - 197810272008121001 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
1804102010061
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Kata Kunci
Penerbit
Banda Aceh : Teknik Mesin dan Industri., 2024
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Studi remaining life assessment terhadap peralatan Heat Exchanger dengan tag number E-101 yang berada di Blang Lancang, Lhokseumawe telah selesai dilaksanakan. Peralatan ini diproduksi tahun 1989.Pemeriksaan eksternal secara visual dan pengambilan data telah dilaksanakan pada 11 september 2023. Dengan mengacu kepada standar dan hasil pengukuran lapangan serta hasil perhitungan yang telah dilakukan, diketahui peralatan tersebut masih layak untuk dioperasikan karena thickness actual masih diatas thickness required. Laju korosi hasil perhitungan menunjukan 0,127 mm/years, sementara Maximum Allowable Working Pressure (MAWP) adalah 500,86 psig atau 35,214 kg/cm2. Estimasi yang dilakukan berdasarkan data hasil pemeriksaan menunjukan bahwa remaining life dari peralatan tersebut diperkirakan 34 tahun. Berdasarkan hasil perhitungan dan analisa yang dilakukan bahwa peralatan Heat Exchanger dengan tag number E-101 masih layak untuk digunakan sejauh tekanan tidak melebihi MAWP hasil perhitungan yang tertera. Metode RBI yang digunakan adalah kuantitaf dengan mangacu pada API 581. Dari hasil analisa dan perhitungan didapatkan bahwa kemungkinan kegagalan dari alat ini berada pada kategori 1, dan konsekuensi kegagalannya berada pada kategori D. Berdasarkan nilai tersebut didapatkan tingkatan resiko dari alat ini berada pada level medium. Interval inspeksi untuk alat ini adalah 4 tahun. Hal ini dikarenakan metode inspeksi tersebut dirasa cocok untuk mendapatkan informasi yang dibutuhkan sesuai dengan mekanisme kerusakan yang dapat terjadi pada alat ini.
The remaining life assessment study on Heat Exchanger equipment with tag number E-101 located in Blang Lancang, Lhokseumawe has been completed. This equipment was manufactured in 1989.Visual external inspection and data collection has been carried out on September 11, 2023. By referring to the standards and the results of field measurements and the results of calculations that have been carried out, it is known that the equipment is still suitable for operation because the actual thickness is still above the required thickness. The corrosion rate calculated shows 0.127 mm / year, while the Maximum Allowable Working Pressure (MAWP) is 500.86 psig or 35.214 kg / cm2. Estimates made based on inspection data show that the remaining life of the equipment is estimated to be 34 years. Based on the results of calculations and analysis carried out that the Heat Exchanger equipment with tag number E-101 is still suitable for use as long as the pressure does not exceed the MAWP calculation results listed. The RBI method used is quantitative based on the API 581 reference. From the results of analysis and calculation, it is found that the possibility of failure of this tool is in category 1, and the consequences of failure are in category D. Based on this value, the risk level of this tool is at the medium level. The inspection interval for this tool is 4 years. This is because the inspection method is considered suitable to obtain the information needed in accordance with the mechanism of damage that can occur in this tool.
REMAINING LIFE ASSESMENT DAN RISK BASE INSPECTION PADA EQUIPMENT MAIN HEAT EXCHANGER DENGAN NOMOR ITEM E-101 (WAN MUHAMMAD HAFIDH, 2024)
KAJIAN PERPINDAHAN PANAS KONVEKSI PADA HEAT EXCHANGER TIPE TUBE DENGAN KONFIGURASI JARAK SIRIP (Dedi Afandi, 2019)
KAJIAN EKSPERIMENTAL KARAKTERISTIK PERPINDAHAN PANAS PADA HEAT EXCHANGER TUBE BERSIRIP CIRCULAR BERPOTONGAN (MUHAMMAD RIDZKI RAMADHANI, 2023)
KAJI EKSPERIMENTAL PENGARUH BESARAN BELOKAN TERHADAP PERFORMANSI PENUKAR PANAS (FIKRI HAIQAL, 2020)
ANALISIS KOMPOSISI MULTI COMPONENT REFRIGERANT (MCR) UNTUK MENINGKATKAN UNJUK KERJA CRYOGENIC HEAT EXCHANGER (Salman A. Rahman, 2025)