ANALISIS PENILAIAN RISIKO KOROSI BETON BERTULANG PADA BANGUNAN MASJID WILAYAH KOTA BANDA ACEH (STUDI KASUS: BABURRAHMAH, TAQWA LHONG RAYA, DAN TAQWA SEUTUI).
Pengarang
ILHAM GEOVANDY - Personal Name;
Dosen Pembimbing
Syarizal Fonna - 197810272008121001 - Dosen Pembimbing I
Nomor Pokok Mahasiswa
1604102010070
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik., 2023
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Baja adalah suatu material yang banyak dipergunakan pada kehidupan kita saat ini. Seperti tulangan penguat di struktur beton bangunan, jembatan dan lain sebagainya. Saat ini penggunaan beton bertulang masih merupakan salah satu metode konstruksi sipil yang paling populer. Akan tetapi, baja memiliki kelemahan. Salah satu kelemahan dari baja yaitu mudah terserang oleh korosi apabila berada di lingkungan yang korosif. Pada pengamatan awal dilakukan pengamatan secara visual pada ketiga bangunan tersebut, secara umum dari ketiga bangunan tersebut sudah mengalami kerusakan pada selimut beton bangunan tersebut. Berdasarkan pengamatan tersebut, perlu dilakukan pengukuran tingkat korosifitas pada area tersebut, sehingga dapat dilakukan antisipasi kerusakan secara tiba-tiba pada struktur bangunan tersebut. Tujuan dari penelitian ini adalah untuk menilai level risiko korosi pada bangunan Masjid Baburrahmah, Masjid Taqwa Lhong Raya, dan Masjid Taqwa Seutui. Half-Cell Potential Mapping merupakan salah satu metode yang digunakan untuk mendeteksi korosi tulangan yang terdapat dalam beton bertulang serta memberikan informasi berupa nilai potensial. Teknik ini hanya dapat mendeteksi risiko serta lokasi korosi. Profometer 5+ merupakan alat yang digunakan untuk mendeteksi posisi tulangan dan sengkang yang ada pada struktur beton bertulangan. Dengan alat ini mampu mengukur ketebalan selimut beton dan merupakan metode tidak merusak. Half-cell Potensial Meter digunakan untuk mengukur nilai potesial korosi dan visualisasi hasil pengukuran nilai potensial korosi menggunakan software open source yang bernama VisIt. Panduan yang digunakan dalam penentuan level risiko korosi adalah ASTM C876. Berdasarkan kriteria level risiko korosi pada ketiga bangunan tersebut, berada pada level risiko korosi rendah (low risk) sampai level risiko korosi sangat tinggi (severe corrosion). Dari ketiga bangunan tersebut level risiko korosi tertinggi terdapat pada bangunan Masjid Taqwa Seutui yang sudah mencapai level risiko korosi sangat tinggi (severe corrosion).
Steel is a material that is widely used in our lives today. Such as reinforcing reinforcement in concrete structures of buildings, bridges and so on. Currently, the use of reinforced concrete is still one of the most popular civil construction methods. However, steel has a weakness. One of the weaknesses of steel is that it is easily attacked by corrosion when it is in a corrosive environment. In the initial observations, visual observations were made on the three buildings, in general all three buildings had experienced damage to the concrete covers of the buildings. Based on these observations, it is necessary to measure the level of corrosiveness in the area, so that sudden damage to the building structure can be anticipated. The aim of this research is to assess the level of corrosion risk in the Baburrahmah Mosque, Taqwa Lhong Raya Mosque and Taqwa Seutui Mosque buildings. Half-Cell Potential Mapping is a method used to detect corrosion of reinforcement in reinforced concrete and provides information in the form of potential values. This technique can only detect risks and locations of corrosion. Profometer 5+ is a tool used to detect the position of reinforcement and stirrups in reinforced concrete structures. This tool is able to measure the thickness of the concrete cover and is a non-damaging method. The Half-cell Potential Meter is used to measure corrosion potential values and visualize the results of measuring corrosion potential values using open source software called VisIt. The guideline used in determining the corrosion risk level is ASTM C876. Based on the criteria for the level of corrosion risk in these three buildings, they are at a low risk level (low risk) to a very high corrosion risk level (severe corrosion). Of the three buildings, the highest level of corrosion risk is found in the Taqwa Seutui Mosque building which has reached a very high level of corrosion risk (severe corrosion).
PENILAIAN RISIKO KOROSI BANGUNAN RUMAH DAN MASJID GAMPONG LAMPOH AWE KABUPATEN PIDIE (MUHAMMAD ZHILAL KHALIQ, 2026)
RISIKO KOROSI BETON BERTULANG PADA WILAYAH KOTA BANDA ACEH: STUDI KASUS PADA BANGUNAN MASJID BAITUSSALAM, DARUL MAKMUR, DAN AL-MUKARRAMAH (M RESTU FURQAN, 2021)
PEMETAAN RISIKO KOROSI BETON BERTULANG PADA MASJID DARUL FALAH GAMPONG PINEUNG – BANDA ACEH (Mohd. Kautsar, 2019)
PEMETAAN ULANG RISIKO KOROSI BETON BERTULANG PADA BAGIAN BARAT MASJID DARUL FALAH, GAMPONG PINEUNG, BANDA ACEH (Harris Ramadhan, 2021)
PEMETAAN RISIKO KOROSI BETON BERTULANG PADA WILAYAH KOTA BANDA ACEH : STUDI KASUS PADA BANGUNAN MASJID BABUTTAQWA, MUSHALLA GAMPONG LUENG BATA, MUSHALLA AL-AZIZI (IHSAN BIYA LUBIS, 2021)