Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
APIKASI DISPOSABLE LIQUID-BASED REFERENCE ELECTRODE PADA MONITORING KOROSI BETON BERTULANG
Pengarang
WAHYU AULIA - Personal Name;
Dosen Pembimbing
Syarizal Fonna - 197810272008121001 - Dosen Pembimbing I
Nomor Pokok Mahasiswa
1704102010067
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik., 2022
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Beton adalah campuran agregat semen, kerikil dan pasir yang menggunakan proses proporsi tertentu pada beton bertulang. Beberapa hal penting harus diperhatikan dalam rangka menjaga umur ketahanan dari infrastruktur tersebut, salah satunya adalah fenomena korosi dalam beton bertulang. Banyak cara untuk menginvestigasi korosi infrastruktur Salah satu komponen utama dalam menginvestigasi suatu korosi tersebut adalah menggunakan reference electrode. Tujuan dari penelitian ini yaitu menguji penggunaan liquid-based reference electrode Cu/CuSO4 untuk mengukur nilai potensial baja yang ditanam langsung kedalam beton bertulang. Beton yang digunakan dengan ukuran panjang 100 mm, lebar 50 mm, dan tinggi 50 mm dan baja tulangan yang digunakan memiliki panjang 120 mm berdiameter 10 mm , benda uji direndam selama 1 bulan dalam media rendaman larutan aquades, NaCl 2,5%, NaCl 3,5%, dan diberi perlakuan wet-dry cycle. Pengukuran nilai potensial baja tulangan menggunakan alat potensiostat dan pengujian yang dilakukan menggunakan metode OCP (Open Circuit Potensial) berdasarkan standar ASTM C876. Hasil pengukuran nilai potensial baja menunjukkan bahwa nilai potensial paling negatif terjadi pada minggu ke-2 dan ke-3. Pada pengukuran nilai potensial korosi baja tulangan, perbandingan antara liquid-based reference electrode Cu/CuSO4 yang di tanam dalam beton, langsung diatas permukaan baja tulangan dan reference electrode Ag/AgCl komersial yang di atas permukaan beton dengan pengujian OCP (open circuit potential) menunjukkan nilai yang di dapat dari hasil pengukuran nilai potensial bahwa pengukuran yang dilakukan langsung ke permukaan baja tulangan mendapatkan nilai potensial korosi yang lebih negatif. Dapat disimpulkan bahwa dari hasil pengukuran yang dilakukan selama 4 minggu menggunakan liquid-based reference electrode Cu/CuSO4 mendapatkan nilai yang lebih baik dalam pengukuran sehingga bisa di aplikasikan dalam monitoring korosi.
Concrete is a mixture of cement, gravel and sand aggregate that uses a certain proportion process in reinforced concrete. Several important things must be considered in order to maintain the durability of the infrastructure, one of which is the phenomenon of corrosion in reinforced concrete. There are many ways to investigate infrastructure corrosion. One of the main components in investigating corrosion is the use of a reference electrode. The purpose of this study is to test the use of a liquid-based reference electrode Cu/CuSO4 to measure the potential value of steel embedded directly into reinforced concrete. The concrete used is 100 mm long, 50 mm wide, and 50 mm high and the reinforcing steel used has a length of 120 mm with a diameter of 10 mm. The test object is immersed for 1 month in a solution of aquades, 2.5% NaCl, NaCl 3 solution. ,5%, and treated with wet-dry cycle. Measurement of the potential value of reinforcing steel using a potentiostat and testing using the OCP (Open Circuit Potential) method based on the ASTM C876 standard. The results of the measurement of the potential value of steel showed that the most negative potential value occurred in the 2nd and 3rd week. In measuring the corrosion potential of reinforcing steel, the comparison between the liquid-based reference electrode Cu/CuSO4 implanted in the concrete, directly on the surface of the reinforcing steel and the commercial Ag/AgCl reference electrode on the surface of the concrete with OCP (open circuit potential) testing shows the value obtained from the results of the potential value measurement that measurements made directly to the surface of the reinforcing steel get a more negative corrosion potential value. It can be concluded that from the results of measurements carried out for 4 weeks using a liquid-based reference electrode Cu/CuSO4 obtained a better value in the measurement so that it can be applied in monitoring corrosion
PENGEMBANGAN DISPOSABLE SOLID-STATE REFERENCE ELECTRODE UNTUK APLIKASI PENGUKURAN POTENSIAL KOROSI PADA BAJA TULANGAN (M. RAFIQI, 2022)
APIKASI DISPOSABLE LIQUID-BASED REFERENCE ELECTRODE PADA MONITORING KOROSI BETON BERTULANG (WAHYU AULIA, 2022)
APLIKASI DISPOSABLE SOLID-STATE REFERENCE ELECTRODE UNTUK PEMANTAUAN KOROSIRNBETON BERTULANG (ZUMADIL ARMADI, 2022)
ANALISIS PENGARUH KETEBALAN SELIMUT BETON TERHADAP SEBARAN POTENSIAL KOROSI RNPADA BAJA TULANGAN MENGGUNAKAN EMBEDDED REFERENCE ELECTRODE (Alvin Aulia Prambudi, 2024)
APLIKASI METODE LINEAR POLARIZATION RESISTANCE (LPR) UNTUK MENGUKUR LAJU KOROSI PADA TULANGAN DALAM BETON BUSA (Romi Hariawan, 2024)