PENGEMBANGAN DISPOSABLE SOLID-STATE REFERENCE ELECTRODE UNTUK APLIKASI PENGUKURAN POTENSIAL KOROSI PADA BAJA TULANGAN
Pengarang
M. RAFIQI - Personal Name;
Dosen Pembimbing
Syarizal Fonna - 197810272008121001 - Dosen Pembimbing I
Nomor Pokok Mahasiswa
1704102010020
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik., 2022
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Reference electrode adalah salah satu komponen alat ukur potensial korosi, selama ini reference electrode yang dipakai bergantung kepada produk komersial yang harganya relatif mahal, sehingga jarang diaplikasikan sebagai disposable reference electrode yang ditanam langsung pada beton untuk pemantauan korosi baja tulangan. Adapun jenis reference electrode yang digunakan dalam pengukuran potensial korosi dapat berupa solid-state atau liquid-based, dengan jenis
solid-state memiliki keuntungan lebih tahan dari kebocoran dibandingkan jenis liquid-based. Tujuan penelitian ini adalah untuk mengembangkan disposable solid-state reference electrode untuk aplikasi pengukuran potensial korosi pada baja tulangan. Reference electrode yang digunakan dalam penelitian ini berfokus pada solid-state reference electrode Cu/CuSO4. Disposable solid-state reference electrode Cu/CuSO4 dibuat dengan bahan utama pipa teflon sebagai body, pelat tembaga sebagai konduktor, CuSO4 sebagai elektrolit dan Larutan DOP + resin PVC + THF sebagai porous plug elektroda. Jumlah reference electrode yang dibuat pada penelitian ini adalah 10 disposable solid-state reference electrode. Pengujian open circuit potential (OCP) dilakukan untuk menguji stabilitas disposable solid-state reference electrode, dengan menggunakan metode voltammetry selama 10 menit dan 10 kali pengulangan pada setiap disposable solid-state reference electrode, serta perbandingan dengan reference electrode Ag/AgCl komersial. Hasil pengukuran menunjukkan nilai potensial korosi yang cukup stabil dari setiap pengujian disposable solid-state reference electrode, dan setelah dibandingkan dengan reference electrode Ag/AgCl komersial, nilai error relative setiap solid-state reference electrode berada dibawah 3,3%. Hasil ini mengindikasikan bahwa disposable solid-state reference electrode berhasil dikembangkan, dan sudah dapat digunakan untuk keperluan kajian korosi seperti kasus korosi bertulang.
Kata kunci : Korosi, Disposable Reference Electrode , Solid-State Reference Electrode .
Reference electrode is one of the components of measuring corrosion potential, so far the reference electrode used depends on commercial products which are relatively expensive, so they are rarely applied as disposable reference electrodes that are planted directly on concrete for corrosion monitoring of reinforcing steel. The type of reference electrode used in measuring corrosion potential can be solid-state or liquid-based, with the type of solid-state has the advantage of being more resistant to leakage than liquid-based types. The aim of this research is to develop a disposable solid-state reference electrode for the application of corrosion potential measurement in reinforcing steel. The reference electrode used in this study focuses on the solid-state reference electrode Cu/CuSO4. Disposable solid-state reference electrode Cu/CuSO4 is made with Teflon pipe as the main material, copper plate as conductor, CuSO4 as electrolyte and DOP solution + PVC resin + THF as porous plug electrode. The number of reference electrodes made in this study was 10 disposable solid-state reference electrodes. The open circuit potential (OCP) test was conducted to test the stability of the disposable solid-state reference electrode, using the voltammetry method for 10 minutes and 10 repetitions for each disposable solid-state reference electrode, as well as comparison with commercial Ag/AgCl reference electrodes. The measurement results show that the corrosion potential value is quite stable from each test of the disposable solid-state reference electrode, and after being compared with the commercial Ag/AgCl reference electrode, the relative error value of each solid-state reference electrode is below 3.3%. These results indicate that a disposable solid-state reference electrode has been successfully developed, and can already be used for corrosion studies, such as in the case of reinforced corrosion. Keywords: Corrosion, Disposable Reference Electrode, Solid-State Reference Electrode.
PENGEMBANGAN DISPOSABLE LIQUID-BASED REFERENCE ELECTRODE PADA APLIKASI PENGUKURAN POTENSIAL KOROSI (ZIKRI ALHILAL HAMDI, 2022)
APLIKASI DISPOSABLE SOLID-STATE REFERENCE ELECTRODE UNTUK PEMANTAUAN KOROSIRNBETON BERTULANG (ZUMADIL ARMADI, 2022)
APIKASI DISPOSABLE LIQUID-BASED REFERENCE ELECTRODE PADA MONITORING KOROSI BETON BERTULANG (WAHYU AULIA, 2022)
ANALISIS PENGARUH KETEBALAN SELIMUT BETON TERHADAP SEBARAN POTENSIAL KOROSI RNPADA BAJA TULANGAN MENGGUNAKAN EMBEDDED REFERENCE ELECTRODE (Alvin Aulia Prambudi, 2024)
PEMETAAN RISIKO KOROSI BETON BERTULANG PADA DERMAGA PELABUHAN PERIKANAN SAMUDERA KUTARAJA GAMPONG LAMPULO - BANDA ACEH (CANDRA SETIAWAN, 2021)