ANALISIS HASIL CITRA CT-SCAN ORGAN TUBUH DENGAN MEDIA KONTRAS IOPAMIDOL 370
Pengarang
KHAIRUNNISA - Personal Name;
Dosen Pembimbing
Adi Rahwanto - 196008091987031003 - Dosen Pembimbing I
Rini Safitri - 197004251995122001 - Dosen Pembimbing I
Nomor Pokok Mahasiswa
1608102010043
Fakultas & Prodi
Fakultas MIPA / Fisika (S1) / PDDIKTI : 45201
Subject
Penerbit
Banda Aceh : Fakultas MIPA (S1)., 2022
Bahasa
Indonesia
No Classification
535
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Telah dilakukan analisis hasil citra CT-Scan dengan media kontras Iopamidol370 pada organ tubuh manusia. Penelitian ini bertujuan untuk mengetahui nilai densitas optik dan juga untuk mengetahui perbedaan hasil citra CT-Scan pada organ tubuh manusia dengan menggunakan media kontras. Nilai densitas optik diperoleh dengan cara menentukan titik objek pada citra organ tubuh manusia dengan software Image-J. dari hasil penelitian menunjukkan bahwa hasil citra organ tubuh manusia yang menggunakan media kontras lebih tajam dibandingkan tanpa penggunaan media kontras. Adapun untuk nilai tertinggi pada densitas optik yaitu 2,275 terdapat pada organ lambung sedangkan nilai densitas optik terendah yaitu 1,986 terdapat pada organ kepala dewasa.
Kata Kunci : CT-Scan, media kontras, citra, densitas optik, Image-J
An analysis of the results of CT-Scan images with Iopamidol370 contrast media has been carried out on human organs. This study aims to determine the value of optical density and also to determine differences in the results of CT-Scan images on human organs using contrast media. The optical density value is obtained by determining the object's point in the image of human organs using Image-J software. from the results of the study showed that the results of the image of human organs using contrast media were sharper than those without the use of contrast media. The highest value for optical density, which is 2.275, is found in the stomach organ, while the lowest optical density value is 1.986, which is found in the adult head organ. Keyword : CT-Scan, contrast media, image, optical density, Image-J
KUANTIFIKASI NILAI DENSITAS OPTIK DAN KONTRAS RESOLUSI DARI HASIL CT-SCAN ABDOMEN (Dewi Mauliyana, 2019)
ESTIMASI DOSIS RADIASI DAN FAKTOR RISIKO PADA PEMERIKSAAN CT SCAN THORAX DI RSUD DR. ZAINOEL ABIDIN DENGAN MEMBEDAKAN PENGGUNAAN MEDIA KONTRAS DANRNNON -KONTRAS (Faradilla Yusfa, 2023)
SEGMENTASI DAN PENENTUAN LUAS CITRA OTAK PADA KASUS STROKE DENGAN METODE ACTIVE CONTOUR DAN K-MEANS CLUSTERING (Amalia Azzarah Rizlin, 2024)
ANALISIS CITRA RONTGEN TORAKS MENGGUNAKAN METODE SEGMENTASI K-MEANS CLUSTERING DAN EDGE DETECTION (RESTY ANGGREINI, 2022)
KARAKTERISTIK PENDERITA SINUSITIS KRONIS BERDASARKAN GAMBARAN CT SCAN TANPA KONTRAS DI POLIKLINIK THT-KL RSUDZA BANDA ACEH (DHIATAMA ENDALIF, 2021)