PENGARUH KANDUNGAN TULANGAN DUA ARAH TERHADAP KUAT TEKAN BETON MUTU TINGGI
Pengarang
HERU MITRA WAHYUDI - Personal Name;
Dosen Pembimbing
Rudiansyah Putra - 197509232002121004 - Dosen Pembimbing I
Nomor Pokok Mahasiswa
1704001010081
Fakultas & Prodi
Fakultas Teknik / Teknik Sipil (D3) / PDDIKTI : 22401
Subject
Kata Kunci
Penerbit
Banda Aceh : Fak. Teknik Sipil Diploma III., 2022
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Beton bermutu tinggi adalah beton yang memiliki kuat tekan antara 40 – 80 MPa. Penggunaan beton mutu tinggi sudah umum digunakan kedalam unsur konstruksi, baik itu yang ada di Indonesia maupun di seluruh dunia. Untuk mengetahui mutu beton di lapangan biasanya dapat dilakukan dengan dua jenis metode pengujian yaitu metode destructive dan metode non-destructive. Pada penelitian ini, pengujian dilakukan dengan menggunakan metode destructive. Pengujian ini menggunakan model beton inti dilapangan yang mana dapat mengetahui kuat tekan beton mutu tinggi jika terkandung tulangan dua arah didalamnya. Benda uji pada beton mutu tinggi ini menggunakan benda uji berbentuk silinder yang berdiameter 10 cm dengan tinggi 20 cm sebanyak 15 buah benda uji. Dari ke-15 buah benda uji tersebut akan dibedakan menjadi tiga kelompok benda uji, diantaranya 5 buah benda uji dengan posisi tulangan 1/2 dari benda uji, 5 buah benda uji dengan posisi tulangan 1/4 dari benda uji, dan 5 buah benda uji tanpa tulangan. Hasil dari penelitian ini menghasilkan nilai rata-rata untuk beton yang menggunakan tulangan posisi 1/2 dari tinggi benda uji bernilai 66,07 N/mm², Setelah di kalikan dengan factor koreksi menghasilkan nilai rata – rata 70,56 N/mm², sedangkan untuk nilai rata – rata pada benda uji yang menggunakan tulangan posisi 1/4 dari tinggi benda uji bernilai 61,30 N/mm²,setelah dikalikan dengan factor koreksi menghasilkan kuat tekan rata – rata bernilai 63,30 N/mm²,dan untuk benda uji tanpa menggunakan tulangan menghasilkan nilai rata – rata 71,25 N/mm². Dari kedua penempatan posisi tulangan dua arah terhadap kuat tekan beton mutu tinggi yang direkomendasikan setelah diteliti yaitu penempatan posisi tulangan 1/2 (berada ditengah tengah tinggi benda uji), disebakan hasil kuat tekan beton rata - rata lebih tinggi dari penempatann dengan posisi tulangan 1/4 dari tinggi benda uji, karna semakin tinggi nilai uji kuat tekan beton otomatis semakin baik juga kualitas beton tersebut untuk digunakan.
Kata kunci: Beton mutu tinggi , kandungan tulangan dua arah , kuat tekan beton.
High-quality concrete is concrete that has a compressive strength between 40-80 MPa. The use of high-strength concrete is commonly used in construction elements, both in Indonesia and throughout the world. To determine the quality of concrete in the field can usually be done with two types of testing methods, namely destructive methods and non-destructive methods. In this study, testing was carried out using the destructive method. This test uses a concrete core model in the field which can determine the compressive strength of high-strength concrete if it contains two-way reinforcement in it. The specimens in this high-strength concrete used cylindrical specimens with a diameter of 10 cm and a height of 20 cm as many as 15 specimens. Of the 15 specimens, the test objects will be divided into three groups of test objects, including 5 test objects with a reinforcement position of 1/2 of the test object, 5 test objects with a reinforcement position of 1/4 of the test object, and 5 test objects. without reinforcement. The results of this study produce an average value for concrete that uses a reinforcement position 1/2 of the height of the test object is 66.07 N/mm², After multiplying by the correction factor it produces an average value of 70.56 N/mm², while for the average value on the test object using the reinforcement position 1/4 of the height of the test object is 61.30 N/mm², after multiplied by the correction factor produces an average compressive strength of 63.30 N/mm², and for the test object without using reinforcement produces an average value of 71.25 N/mm². From the two placements of the two-way reinforcement position to the compressive strength of high-strength concrete which is recommended after research, namely the placement of the reinforcement position 1/2 (in the middle of the height of the test object), because the results of the average compressive strength of concrete are higher than the placement with the reinforcement position 1/ 4 of the height of the test object, because the higher the value of the automatic concrete compressive strength test, the better the quality of the concrete to use.
PENGARUH KANDUNGAN TULANGAN SATU ARAH TERHADAP KUAT TEKAN BETON MUTU TINGGI DENGAN BENDA UJI SILINDER DIAMETER 10X10 CM (SAMSUIR, 2022)
PENGARUH KANDUNGAN TULANGAN DUA ARAH TERHADAP KUAT TEKAN BETON MUTU TINGGI (HERU MITRA WAHYUDI, 2022)
PENGARUH KANDUNGAN TULANGAN DUA ARAH TERHADAP KUAT TEKAN BETON MUTU TINGGI DENGAN BENDA UJI SILINDER DIAMETER 10X10CM (MULISSARUDIN, 2022)
ANALISIS KAPASITAS LENTUR BALOK BETON BERTULANG MUTU TINGGI DENGAN MENGGUNAKAN CANGKANG SAWIT SEBAGAI SUBTITUSI AGREGAT KASAR (Rizky Amelia Farida, 2016)
ANALISIS KAPASITAS GESER BALOK BETON BERTULANG MUTU TINGGI DENGAN MENGGUNAKAN CANGKANG SAWIT SEBAGAI SUBSTITUSI AGREGAT KASAR (CUT ZARA HALLA SAJIDA, 2016)