Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
ANALISIS PERFORMANSI KOMPRESOR UDARA SENTRIFUGAL 61-101-J DENGAN KAPASITAS 60 TON/JAM DI PT. PUPUK ISKANDAR MUDA
Pengarang
MUHAMMAD RAJA KHAMAINI - Personal Name;
Dosen Pembimbing
Ahmad Syuhada - 196108201987031002 - Dosen Pembimbing I
Ratna Sary - 197811082006042002 - Dosen Pembimbing II
Syahriza - 196708081994031005 - Penguji
Sarwo Edhy S - 198106262006041005 - Penguji
Akram - 197606012006041003 - Penguji
Nomor Pokok Mahasiswa
1604102010069
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik., 2022
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Kompresor merupakan alat termodinamika yang berfungsi untuk memampatkan udara sehingga mencapai tekanan tertentu. Tekanan yang dicapai biasanya lebih tinggi dari tekanan udara lingkungan (1 atm). Kompresor yang digunakan pada PT. Pupuk Iskandar Muda merupakan kompresor udara sentrifugal 4 tingkat yang berfungsi sebagai penyuplai udara proses, udara anti korosi pada pabrik urea serta kebutuhan udara instrument, bagging dan lainnya. Berdasarkan studi lapangan yang telah dilakukan di PT. Pupuk Iskandar Muda, sering terjadinya surge pada kompresor udara sentrifugal 61-101-J yang dikarenakan mass flow rendah yang jika dibiarkan dapat mempengaruhi performa kompresor serta meningkatkan beban kerja pada penggerak kompresor, hal ini disebabkan oleh filter udara yang kotor atau rusak, dan umur dari unit tersebut telah beroperasi selama 22 tahun. Untuk itu perlu sekiranya mengetahui nilai performa dari kompresor udara sentrifugal 61-101-J setelah dilakukannya pemeliharaan, agar mengetahui kompresor tersebut masih layak beroperasi atau tidak. Perhitungan performa kompresor dilakukan berdasarkan data operasional sebelum maintenance dan setelah maintenance. Performa kompresor yang akan dihitung yaitu efisiensi politropik, head politropik, kapasitas inlet volume flow, dan daya kompresor. Selanjutnya hasil perhitungan performa operasional kompresor dibandingkan dengan performa kompresor berdasarkan spesifikasi. Setelah dilakukan perhitungan performa kompresor, dapat disimpulkan bahwa kondisi kompresor setelah maintenance lebih baik jika dibandingkan dengan kondisi kompresor sebelum maintenance. Kondisi kompresor masih layak beroperasi karena efisiensi rata-rata kompresor setelah maintenance sebesar 78,7% dan total daya kompresor setelah maintenance adalah 8413 KW.
Compressor is a thermodynamic device that functions to compress air so that it reaches a certain pressure. The pressure achieved is usually higher than the ambient air pressure (1 atm). The compressor used at PT. Pupuk Iskandar Muda is a 4-stage centrifugal air compressor that functions as a supplier of process air, anti-corrosion air in the urea plant as well as instrument, bagging and other air needs. Based on field studies that have been conducted at PT. Pupuk Iskandar Muda, frequent surges in the 61-101-J centrifugal air compressor due to low mass flow which if left unchecked can affect compressor performance and increase the workload on the compressor drive, this is caused by dirty or damaged air filters, and the age of the compressor. The unit has been operating for 22 years. For this reason, it is necessary to know the performance value of the 61-101-J centrifugal air compressor after maintenance, in order to find out whether the compressor is still feasible to operate or not. Compressor performance calculation is based on operational data before and after maintenance. Compressor performance to be calculated is polytropic efficiency, polytropic head, inlet volume flow capacity, and compressor power. Furthermore, the results of the calculation of the operational performance of the compressor are compared with the performance of the compressor based on the specifications. After calculating the performance of the compressor, it can be concluded that the condition of the compressor after maintenance is better than the condition of the compressor before maintenance. The condition of the compressor is still feasible to operate because the average efficiency of the compressor after maintenance is 78.7% and the total compressor power after maintenance is 8413 KW.
PERBAIKAN KOMPRESOR SETRIFUGAL DI PT PUPUK ISKANDAR MUDA (PIM) KRUENG GEUKUEH ACEH UTARA (Abizar, 2018)
ANALISA DAYA KOMPRESOR GAS RECIPROCATING TYPE INGERSOLL-RAND ANALISA DAYA KOMPRESOR GAS RECIPROCATING TYPE INGERSOLL-RAND (Teuku Syahrul, 2016)
KEGIATAN MAINTENANCE INJEKTOR DAN KOMPRESOR PADA MESIN SORTIR BIJI KOPI BERDASARKAN WARNARNDI PERUSAHAAN KBQ BABURRAYYAN (Feri Wahyudi, 2021)
ANALISIS UNJUK KERJA KOMPRESOR SENTRIFUGAL PADA UNIT FLARE GAS RECOVERY PT ARUN, NGL (TEUKU JULIADI, 2025)
PERAWATAN PADA KOMPRESOR TIPE (RECIPROCATING) DI PT PERTAMINA GAS EASTERN JAVA AREA (M IRVAN HAIDAR, 2019)