PERKIRAAII SAAT KEMATIAN BERDASARKANRNPENURUNAN SUHU TUBUH MAYAT DENGANRNMENGGUNAKAN TERMOMETER DIGITALRNPADA AKSILA | ELECTRONIC THESES AND DISSERTATION

Electronic Theses and Dissertation

Universitas Syiah Kuala

    SKRIPSI

PERKIRAAII SAAT KEMATIAN BERDASARKANRNPENURUNAN SUHU TUBUH MAYAT DENGANRNMENGGUNAKAN TERMOMETER DIGITALRNPADA AKSILA


Pengarang

dara meutia ayu febrina - Personal Name;

Dosen Pembimbing



Nomor Pokok Mahasiswa

0807101050073

Fakultas & Prodi

Fakultas / / PDDIKTI :

Subject
Penerbit

Banda Aceh : Fakultas Kedokteran., 2012

Bahasa

Indonesia

No Classification

612.016 26

Literature Searching Service

Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)

ABSTK4CT
Shortly a/ier the death v,oLrld otcur the change.s that probubLy, e.tti tote tirne of the
tleuth. One of the changes ttre a decreuse of post-nofiem tetnperuture as meosured by
tanalometer lhrough rectLtnt. ,\lodiJicution oJ the nrcttsuremenl v'ith tligitul lo otoDret$ on
the a:illa bccause of'rhe diJJicttlty to.find the tonatometer. Thi.s stutll, v'us contlucted to
tletermine relationship on.l patterns ol decline in botly temperutu'e os measttred by digirul
lonotomeler on the axilla to the upproximate length oJ time oJ deoth and ohtuin usimple
equ ion estimated time o.f the deurh. The study design ol'this stuLly trus obsenational v'ilh
cross-stclional approuch. The lechnique sampling used is total sanpling wilh concerning to
inclusion ctnd exclttsion criterias. This shttly tvas utndttcletl Jrom ,lanuary, l't to l,lurch, 3(/h
2012 *'ith 35 people as somples. The stutly datas was obatainetl fi'om meosuremcnts o.f body
temperoture in the inpatient room RSUDZA with digital tandlonrcter on the @iilla.for Lr
momment. 30 minute.s and 60 minutes aJier deuth. Room temperatLtre was measto'e(l at same
time. The resak ol srotistic t-test shou'ed signiJicant differences in temperature bety'een time
[) minute, 30 minutes, ond 60 minutes. The restit of correlation test shoy,ed thut there is cr
very slrong relationship bet*-een the decrease in body temperature as measured )t,ith digitt
thermometer on the axilla to the prediction of the length o/ lime ol deoth with a correlation
coelJicient oJ 0.999 which.form a linear patlern of negative andfound no platectu in lhe tarltime
oJ'death. The results of this study also resulted in similarity regression of )'= 831.950 to
22.891 x thal con be ttsed to estimote the time of dedh at the beginning oJ death.
Keltvords: body temperature, post-mortem, time ofdeuth

Tidak Tersedia Deskripsi

Citation



    SERVICES DESK