<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" id="75210">
 <titleInfo>
  <title>BAND LIMITED PHASE ONLY CORRELATION (BLPOC) UNTUK APLIKASI PENCOCOKAN IRIS MATA</title>
 </titleInfo>
 <name type="Personal Name" authority="">
  <namePart>Cendikia Perbawa ZK</namePart>
  <role>
   <roleTerm type="text">Primary Author</roleTerm>
  </role>
 </name>
 <typeOfResource manuscript="no" collection="yes">mixed material</typeOfResource>
 <genre authority="marcgt">bibliography</genre>
 <originInfo>
  <place>
   <placeTerm type="text">Banda Aceh</placeTerm>
   <publisher>Universitas Syiah Kuala</publisher>
   <dateIssued>2020</dateIssued>
  </place>
 </originInfo>
 <language>
  <languageTerm type="code">id</languageTerm>
  <languageTerm type="text">Indonesia</languageTerm>
 </language>
 <physicalDescription>
  <form authority="gmd">Null</form>
  <extent></extent>
 </physicalDescription>
 <note>Irides can be used as personal identity because some of their nature, that is stable, has a diverse physical structure and does not depend on the genetic trait Research on this final project aims to obtain and analyze the results of iris matching process using low frequency phase (band limited phase only correlation), and find out how much low frequency  that  produces  the maximum  peak and  find out how weJI  the band limited phase-only correlation (BLPOC) compared to phase only correlation (POC). Iris  recognition   systems   are  discussed  starting  with  the  process  of automatic segmentation based on Hough transform to localize the circular iris and pupil. Then the  system   extracts  and  normalizes  the  irides  into  a  rectangular   shape  with dimensions 240 x 20 pixels (full circle of iris image), 120 x 20 pixels(½ circle of iris image)  and  60 x  20 pixels  (¼  circle  of iris image). Normalized  irides were  then correlated  using  a BLPOC.  Correlation  based on POC  on  ¼  circle  normalization resulted in 50% accuracy.  While correlation based on BLPOC on the same condition in a higher accuracy level, that is 80%.&#13;
&#13;
Keywords: Iris, Fourier Transform, Band Limited Phase Only Correlation.&#13;
&#13;
&#13;
&#13;
</note>
 <classification>0</classification>
 <identifier type="isbn"></identifier>
 <location>
  <physicalLocation>ELECTRONIC THESES AND DISSERTATION Universitas Syiah Kuala</physicalLocation>
  <shelfLocator></shelfLocator>
 </location>
 <slims:digitals/>
</mods>
<recordInfo>
 <recordIdentifier>75210</recordIdentifier>
 <recordCreationDate encoding="w3cdtf">2020-08-19 14:58:20</recordCreationDate>
 <recordChangeDate encoding="w3cdtf">2020-08-19 15:56:24</recordChangeDate>
 <recordOrigin>machine generated</recordOrigin>
</recordInfo>
</modsCollection>