<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" id="53687">
 <titleInfo>
  <title>SISTEM MONITORING POWER SUPPLY REPEATER RADIO SCADA PT. PLN (PERSERO) APD ACEH  MONITORING SYSTEM POWE SUPPLY REPEATER RADIO SCADA PT. PLN (PERSERO)APD ACEH</title>
 </titleInfo>
 <name type="Personal Name" authority="">
  <namePart>Nanda Nurmaulida</namePart>
  <role>
   <roleTerm type="text">Primary Author</roleTerm>
  </role>
 </name>
 <typeOfResource manuscript="no" collection="yes">mixed material</typeOfResource>
 <genre authority="marcgt">bibliography</genre>
 <originInfo>
  <place>
   <placeTerm type="text">Banda Aceh</placeTerm>
   <publisher>Universitas Syiah Kuala</publisher>
   <dateIssued>2019</dateIssued>
  </place>
 </originInfo>
 <language>
  <languageTerm type="code">id</languageTerm>
  <languageTerm type="text">Indonesia</languageTerm>
 </language>
 <physicalDescription>
  <form authority="gmd">Null</form>
  <extent></extent>
 </physicalDescription>
 <note>ABSTRACT&#13;
&#13;
RADIO REPEATER POWER SUPPLY MONITORING SYSTEM&#13;
SCADA PT PLN (PERSERO) APD ACEH&#13;
&#13;
By&#13;
NANDA NURMAULIDA&#13;
1404005010014&#13;
&#13;
	Radio repeater power supply monitor is a device based on ATMEGA-8 microcontroller. This device  supervised power supply and battery condition in realtime. If problem occur, this device sending an information over Short Message Service (SMS) to admin. Power supply damage is overvoltage and undervoltage. If power supply damage occur, this device will shutdown the power source to repeater, so that will not damage repeater.&#13;
	If main source 220V absence, this device automatically transfer power source from power supply to battery. That will keep repeater operated. While battery voltage reach below 11 volt, this device will shutting down repeater power source, so battery not damage because overdischarge. &#13;
&#13;
Keyword : AVR, ATMEGA-8,  repeater, SMS, power supply, ATS (automatic transfer switch)&#13;
</note>
 <classification>0</classification>
 <identifier type="isbn"></identifier>
 <location>
  <physicalLocation>ELECTRONIC THESES AND DISSERTATION Universitas Syiah Kuala</physicalLocation>
  <shelfLocator></shelfLocator>
 </location>