PENGARUH PEMBEBANAN LEBIH PADA GARDU DISTRIBUSI PENYULANG SYIAH KUALA PADA PT.PLN RAYON MERDUATI
Pengarang
IZZIAH KARAMI - Personal Name;
Dosen Pembimbing
Nomor Pokok Mahasiswa
1504005010031
Fakultas & Prodi
Fakultas Teknik / Teknik Listrik (D3) / PDDIKTI : 20403
Subject
Kata Kunci
Penerbit
Banda Aceh : Universitas Syiah Kuala., 2018
Bahasa
Indonesia
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
INTISARI
Transformator Distribusi memiliki kapasitas daya tertentu sehinggan dalam penggunaanya harus disesuaikan dengan beban di suatu lokasi agar tidak melebihi kemampuan kapasitas dayanya. Hal ini perlu diperhatikan karena pembebanan lebih pada Transformator akan mempengaruhi performansi transformator tersebut. Transformator pada gardu distribusi penyulang syiah kuala Banda Aceh Sebagian Besar mengalami pembebanan lebih, oleh karena itu penelitian ini dilakukan untuk mengetahui pengaruh pembebanan lebih terhadap sisa umur atau pengurangan umur Transformator pada saat pembebanan lebih. Untuk mengetahui pengaruh tersebut dilakukan analisa data bedasarkan data beban transformator. Hasil analisa menunjukkan bahwa pembebanan lebih menyebabkan terjadinya pengurangan umur transformator. Pada Pembebanan 91,25% pada 200 KVA sisa umur pada transformator yaitu 1,14 jam/hari, Semakin besar bebannya maka semakin besar pengurangan umurnya semakin kecil bebannya semakin kecil pula penguran umurnya.
Kata Kunci : PT.PLN Merduati, Transformator.
ABSTRACT
A distribution transformer has a certain rating power capacity in its appliance. Theoretically, a transformer cannot be used to supply the load that needs power greater than the transformer rating power capacity. Due to this reason, it has to be used as suggested in its nominal power capacity to serve the load at a typical location. Overloaded transformer will result in reducing its performances. Most of transformers located in Banda Aceh substation experience overloaded. Therefore, the objective of this investigation is to examine the effect of overloaded transformer to the age reduction of transformer when it is overloaded. To know the effect of it, data analysis is conducted based on the data of transformer’s load. The result of the data analysis shows that overloaded transformer will result in transformer’s age reduction. The age reduction of the transformer whose load is 91.25% with 200 KVA is 1.14 hour/day. As a result, the greater the load of a transformer has, the greater the age reduction happens, and vice versa.
Kata Kunci : PT.PLN Merduati, Transformer
Tidak Tersedia Deskripsi
ANALISA JATUH TEGANGAN JARINGAN DISTRIBUSI PRIMER 20KV PADA PENYULANG INDRAPURI (STUDI KASUS PADA PT. PLN (PERSERO) RAYON LAMBARO) (Rahmat Akbar, 2016)
PENGARUH PEMBEBANAN LEBIH PADA GARDU DISTRIBUSI PENYULANG SYIAH KUALA PADA PT.PLN RAYON MERDUATI (IZZIAH KARAMI, 2018)
ANALISA ALIRAN DAYA DENGAN BEBAN TIDAK SEIMBANG PADA PENYULANG BLANG BINTANG GARDU HUBUNG LAMBARO (Ridha Firdaus, 2024)
PENGGUNAAN KWH METER PRABAYAR OLEH PT.PLN (PERSERO) RAYON MERDUATI SEBAGAI TEKNIK PENCEGAHAN PENCURIAN LISTRIK (JUWITA AMANDA, 2018)
STUDI PENEMPATAN TRANSFORMATOR DISTRIBUSI 20 KV BERDASARKAN JATUH TEGANGAN PADA PENYULANG ULEE LHEUE (STUDI KASUS PADA PT.PLN (PERSERO) KOTA BANDA ACEH) (TEUKU FITRIADI, 2014)