Electronic Theses and Dissertation
Universitas Syiah Kuala
THESES
EFISIENSI PERKUATAN KOLOM GEDUNG BERLANTAI 4 DENGAN BEBERAPA ALTERNATIF METODE PERKUATAN
Pengarang
Dara Aulia Ulfa - Personal Name;
Dosen Pembimbing
Nomor Pokok Mahasiswa
2404201010080
Fakultas & Prodi
Fakultas Teknik / Teknik Sipil (S2) / PDDIKTI : 22101
Penerbit
Banda Aceh : Fakultas Teknik., 2026
Bahasa
Indonesia
No Classification
690.13
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Kota Banda Aceh berada pada kawasan yang dipengaruhi oleh zona megathrust Aceh -Andaman sehingga memiliki tingkat kerawanan gempa yang tinggi. Penelitian ini meninjau kolom bangunan hotel empat lantai yang dialihfungsikan menjadi rumah sakit, sehingga diperlukan evaluasi kapasitas dan perkuatan struktur akibat perubahan fungsi bangunan. Data eksisting diperoleh dari laporan assessment, berupa hasil analisis struktur menggunakan ETABS. Selanjutnya, perhitungan kapasitas aksial dan geser serta perencanaan perkuatan dilakukan secara manual dengan mengacu pada data gaya dalam hasil analisis ETABS. Tiga metode perkuatan yang ditinjau adalah concrete jacketing, steel plate jacketing, dan ferrocement jacketing. Evaluasi struktur dilakukan sesuai SNI 2019 tentang Persyaratan Beton Struktural untuk bangunan gedung dan estimasi biaya menggunakan analisa harga satuan pekerjaan (AHSP) Tahun 2026 dan Peraturan Pemerintah Aceh No.3 Tahun 2026. Hasil perkuatan concrete jacketing menunjukkan peningkatan kapasitas aksial sebesar 32% dan kapasitas geser mencapai 105,9 % serta memerlukan biaya pelaksanaan sebesar Rp. 2.111 / kN. Metode steel plate jacket menghasilkan peningkatan kapasitas aksial sebesar 1,75% dan kapasitas geser sebesar 183,3% dengan biaya sebesar Rp. 8.178 / kN. Sementara itu, pada perkuatan ferrocement jacket diperoleh peningkatan kapasitas aksial mencapai 2,30% dan kapasitas geser sebesar 170,53% serta membutuhkan biaya sebesar Rp. 2.414 / kN. Berdasarkan hasil evaluasi, ketiga metode perkuatan mampu memenuhi kebutuhan kapasitas struktur sehingga kolom dinyatakan aman untuk mendukung perubahan fungsi bangunan. Namun, ditinjau dari aspek efisiensi biaya dan peningkatan kapasitas yang diperoleh, ferrocement jacket menjadi metode yang menghasilkan biaya pelaksanaan yang paling rendah dan direkomendasikan sebagai solusi perkuatan kolom pada bangunan eksisting dengan karakteristik serupa.
Kata Kunci : Kolom, Concrete jacketing, Steel Plate Jacketing, Ferrocement Jacket, Analisis Biaya
Banda Aceh is located in an area influenced by the Aceh–Andaman megathrust zone, making the region highly vulnerable to earthquakes. This study examines the structural capacity of columns in a four-story hotel building that is being converted into a hospital, requiring structural evaluation and strengthening due to changes in building function and load demands. The existing structural data were obtained from an assessment report based on structural analysis using ETABS. Axial and shear capacities, as well as the strengthening designs, were subsequently evaluated through manual calculations using the internal forces obtained from the ETABS analysis. Three strengthening methods were investigated: concrete jacketing, steel plate jacketing, and ferrocement jacketing. Structural evaluation was conducted in accordance with SNI 2847:2019 concerning structural concrete requirements for buildings, while construction costs were estimated using the 2026 Unit Price Analysis (AHSP) and Aceh Government Regulation No. 3 of 2026. The results indicate that concrete jacketing increased the axial capacity by 32% and the shear capacity by 105.9%, with an implementation cost of Rp 2,111/kN. Steel plate jacketing increased the axial capacity by 1.75% and the shear capacity by 183.3%, with a cost of Rp 8,178/kN. Meanwhile, ferrocement jacketing increased the axial capacity by 2.30% and the shear capacity by 170.53%, with an implementation cost of Rp 2,414/kN. All three strengthening methods satisfied the required structural capacities, indicating that the columns are adequate for the proposed change in building function. Considering the balance between capacity improvement and construction cost, ferrocement jacketing provides an efficient strengthening alternative for existing columns with similar characteristics Keywords: Column, Concrete jacketing, Steel Plate Jacketing, ferrocement Jacket, Cost Analysis.
PENGGUNAAN NATURAL FIBER REINFORCED POLYMER (NFRP) BERBAHAN DASAR SERAT PISANG ABAKA UNTUK PERKUATAN GESER BALOK BETON BERTULANG (MUHAMMAD IQBAL, 2020)
STRATEGI PERKUATAN STRUKTUR BANGUNAN ATAS GEDUNG ASRAMA PESANTREN INSHAFUDDIN (STUDI KASUS KEGAGALAN AKIBAT GEMPA) (Halida yunita, 2025)
PERKUATAN BALOK GAGAL GESER DENGAN MATRIX FERROFOAM CONCRETE BERSERAT POLYETHYLENE (Muhammad Al - Kautsar Karsa, 2026)
STUDI EKSPERIMENTAL KUAT GESER KOLOM DENGAN PERKUATAN EKSTERNAL NFRP SERAT ABAKA PADA VARIASI KETEBALAN LAPIS (MUYASSARAH MAHARANI, 2026)
KAPASITAS KUAT LENTUR BETON DENGAN PERKUATAN EKSTERNAL NATURAL FIBER REINFORCED POLYMER (NFRP) BERBAHAN SERAT ABAKA RAJUT TIDAK RAPAT (MUHAMMAD SHARHAN ARMIA, 2022)