Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
KONTRUKSI ELEKTRODA SELEKTIF ION (ESI) CR3+ BERBASIS MEMBRAN POLIURETAN TERMODIFIKASI GRAPHENE DAN MOLECULAR IMPRINTED POLYMER (MIP-CR(III)) SECARA POTENSIOMETRI
Pengarang
Cut Ratu Dhiya Ulhaq - Personal Name;
Dosen Pembimbing
Eka Safitri - 197001052000032001 - Dosen Pembimbing I
Nomor Pokok Mahasiswa
2108103010011
Fakultas & Prodi
Fakultas MIPA / Kimia (S1) / PDDIKTI : 47201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas MIPA Kimia., 2026
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Telah dilakukan penelitian mengenai pembuatan elektroda selektif ion Cr3+ berbasis membran poliuretan (PU) menggunakan minyak jarak (Ricinus Communis L.) yang dimodifikasi dengan graphene dan Molecular Imprinted Polymer (MIP). Karakterisasi FTIR menunjukkan terbentuknya ikatan uretan pada bilangan gelombang 3331 cm-1, keberadaan MIP ditunjukkan oleh serapan -OH dan C=N masing-masing pada 3522 cm-1 dan 2374 cm-1, sedangkan keberadaan graphene dibuktikan dengan adanya pergeseran pita serapan C=O pada bilangan gelombang 1749 cm-1. Membran PU bersifat amorf dengan permukaan luar padat kasar dan relatif halus. Hasil penelitian menunjukkan bahwa komposisi terbaik yang diperoleh pada penggunaan membran yang mengandung 3 mg MIP menggunakan larutan internal KCl 0,1 M : Cr(NO3)3 0,1 M dengan nilai rata-rata faktor Nernst -21,546 ± 1,06 mV/dekade dengan rentang pengukuran 10-10–10-4 M, koefisien determinasi (R2) 0,988, waktu respon 300 detik, serta limit deteksi 1,29 x 10-15 M.
Research has been carried out on the manufacture of Cr3+ ion selective electrodes based on polyurethane (PU) membranes using castor oil (Ricinus Communis L.) modified with graphene and Molecular Imprinted Polymer (MIP). FTIR characterization shows the formation of urethane bonds at wave number 3331 cm-1, the presence of MIP is indicated by -OH and C=N absorption at 3522 cm-1 and 2374 cm-1 respectively, while the presence of graphene is proven by a shift in the C=O absorption band at wave number 1749 cm-1. PU membranes are amorphous with a rough and relatively smooth solid outer surface. The research results showed that the best composition was obtained when using a membrane containing 3 mg MIP using an internal solution of 0,1 M KCl : 0,1 M Cr(NO3)3 with an average Nernst factor value of -21,546 ± 1,06 mV/decade with a measurement range of 10-10-10-4 M, a correlation coefficient (r) of 0,988, a response time of 300 seconds, and a detection limit of 1,29 x 10-15 M.
PEMBUATAN ELEKTRODA SELEKTIF ION (ESI) AL3+ BERBASIS MEMBRAN POLIURETAN DARI MINYAK JARAK TERMODIFIKASI 1,10-FENANTROLIN & GRAPHENE (RESTU RAHMI, 2022)
PENENTUAN KOEFISIEN SELEKTIVITAS (KIJ) ELEKTRODA SELEKTIF ION (ESI) AL3+ BERBASIS MEMBRAN POLIURETAN TERMODIFIKASI GRAPHENE DAN 1,10-FENANTROLIN (REHAN AFIFAH HANJAYA, 2023)
STUDI OPTIMASI ELEKTRODA SELEKTIF ION (ESI) MG2+ BERBASIS MEMBRAN POLIURETAN DARI MINYAK JARAK (RICINUS COMMUNIS L.) DENGAN BAHAN AKTIF EKSTRAK KLOROFIL DARI DAUN SUJI (PLEOMELE ANGUSTIFOLIA) (Zalsha Rizka Humaira Rangkuti, 2024)
PEMBUATAN ELEKTRODA SELEKTIF ION CR3+ BERBASIS MEMBRAN POLIURETAN TERMODIFIKASI GRAPHENE (Rada Humaira, 2023)
PEMBUATAN ELEKTRODA SELEKTIF ION CR3+ BERBASIS MEMBRAN POLIURETAN BERBAHAN AKTIF 1,10-FENANTROLIN (Ulul Albab, 2021)