Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
UJI SISTEM PENUKAR KALOR PADA MENARA PENDINGIN TIPE PLAT BERTINGKAT DAN BERLUBANG DENGAN PERMUKAAN PLAT BERGELOMBANG
Pengarang
MUNADHIRAH - Personal Name;
Dosen Pembimbing
Ahmad Syuhada - 196108201987031002 - Dosen Pembimbing I
Ratna Sary - 197811082006042002 - Dosen Pembimbing I
Nomor Pokok Mahasiswa
2104102010057
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik., 2025
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Menara pendingin merupakan komponen penting dalam industri untuk proses pertukaran kalor. Penelitian ini bertujuan untuk menganalisis pengaruh variasi jarak gelombang pada plat aluminium berlubang bulat dengan kemiringan 15° terhadap kinerja menara pendingin tipe plat bertingkat. Variasi jarak yang digunakan adalah 70 mm, 90 mm, dan 110 mm, dengan variasi temperatur air masuk sebesar 65°C, 75°C, dan 85°C. Pengukuran temperatur dilakukan pada 12 titik sepanjang menara pendingin untuk menganalisis distribusi temperatur dan laju perpindahan panas. Hasil penelitian menunjukkan bahwa variasi jarak gelombang berpengaruh signifikan terhadap efisiensi pendinginan. Jarak 70 mm menghasilkan laju perpindahan panas tertinggi, yaitu sebesar 36636,72 J/s pada temperatur masuk 85°C, dibandingkan dengan jarak 90 mm (35771,28 J/s) dan 110 mm (32598,02 J/s). Koefisien perpindahan panas konveksi juga tertinggi pada jarak 70 mm, yaitu 3872,36 W/m²K untuk temperatur 65°C. Hal ini disebabkan oleh turbulensi aliran yang lebih intens dan pengurangan ketebalan lapisan batas termal. Dengan demikian, dapat disimpulkan bahwa penggunaan plat bergelombang dengan jarak 70 mm dapat meningkatkan laju perpindahan panas menara pendingin secara signifikan.
Cooling towers are an important component in industry for heat exchange processes. This study aims to analyze the effect of wave distance variations on perforated aluminum plates with a 15° slope on the performance of multi-plate cooling towers. The variations in distance used were 70 mm, 90 mm, and 110 mm, with variations in water inlet temperature of 65°C, 75°C, and 85°C. Temperature measurements were taken at 12 points along the cooling tower to analyze the temperature distribution and heat transfer rate. The results showed that the variation in wave distance had a significant effect on cooling efficiency. The 70 mm spacing produced the highest heat transfer rate, which was 36636,72 J/s at an inlet temperature of 85°C, compared to 90 mm (35771,28 J/s) and 110 mm (32598,02 J/s). The convective heat transfer coefficient was also highest at a distance of 7 cm, namely 3872,36 W/m²K for a temperature of 65°C. This was due to more intense flow turbulence and a reduction in the thickness of the thermal boundary layer. Thus, it can be concluded that the use of corrugated plates with a distance of 70 mm can significantly increase the heat transfer rate of cooling towers.
KAJIAN EKSPERIMENTAL PENGARUH JUMLAH LUBANG PLAT TERHADAP PERPINDAHAN PANAS KONVEKSI PADA MENARA PENDINGIN TIPE PLAT DATAR (Asra Yufandi, 2021)
UJI SISTEM PENUKAR KALOR PADA MENARA PENDINGIN TIPE PLAT BERTINGKAT DAN BERLUBANG DENGAN PERMUKAAN PLAT BERGELOMBANG (MUNADHIRAH, 2025)
ANALISA PERPINDAHAN PANAS PADA MENARA PENDINGIN TIPE PLAT DATAR BERLUBANG (Elfia Ridwan, 2024)
KAJIAN KARAKTERISTIK PERPINDAHAN PANAS PADA MENARARNPENDINGIN TIPE PLAT DATAR BERTINGKAT AKIBAT PENGARUHRNLETAK LUBANG (AFDHALUL RAJAI, 2022)
ANALISA PENGARUH JUMLAH LUBANG PADA MENARA PENDINGIN TIPE PLAT DATAR BERTINGKAT BANYAK TERHADAP KARAKTERISTIK PERPINDAHAN PANAS (ALIFIA KANEYSHA PERANGIN-ANGIN, 2024)