PERHITUNGAN NILAI DOSIS EFEKTIF (DE) COMPUTED TOMOGRAPHY SCANNING PARU-PARU MENGGUNAKAN SOFTWARE INDOSECT V20B
Pengarang
Gusfani Aulia Putri - Personal Name;
Dosen Pembimbing
Evi Yufita - 197509202000122001 - Dosen Pembimbing I
Elin Yusibani - 197903232006042002 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
2108102010009
Fakultas & Prodi
Fakultas MIPA / Fisika (S1) / PDDIKTI : 45201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas MIPA Fisika., 2025
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Penelitian ini bertujuan untuk menghitung nilai dosis efektif (DE) Computed Tomographt Scanning Paru-Paru Menggunakan Software IndoseCT v20b. Data perhitungan yang akan dibandingkan dengan perhitungan seacara matematis sebanyak empat data DICOM dianalisis dengan lima slices per pasien. Metode yang digunakan pada penelitian ini adalah metode perhitungan secara matematis dan software IndoseCT v20b. Hasil menunjukkan bahwa nilai DE dari software lebih rendah dan konsisten dibandingkan secara matematis, dengan rata-rata perbedaan sebesar ±43,3% dengan rentang antara ±35%–61,5%. Dosis radiasi Software IndoseCT v20b didapatkan masih dibawah standar BAPETEN, sehingga direkomendasikan digunakan untuk menghitung pengelolaan dosis radiasi pasien.
The effective dose (ED) of lung computed tomography (CT) scans was calculated using IndoseCT v20b software and compared with values obtained through manual mathematical calculations. A total of four DICOM datasets were analyzed, with five image slices evaluated per patient. The methode used in this case is calculated with mathematics and software IndpseCT v20b. The findings revealed that the ED values generated by the software were consistently lower and more uniform than those obtained mathematically, with an average percentage difference of ±43.3%, ranging from ±35% to 61.5%. Additionally, the radiation dose estimates provided by IndoseCT v20b remained below the reference limits established by BAPETEN. These results support the use of IndoseCT v20b as a reliable tool for estimating and managing patient radiation exposure in clinical CT imaging.
PENGUKURAN NILAI COMPUTER TOMOGRAPHY DOSE INDEX (CTDI) DAN DOSE LENGTH PRODUCT (DLP) PADA PEMERIKSAAN MULTISLICE COMPUTED TOMOGRAPHY (MSCT) DIAGNOSA KANKER PARU-PARU DI INSTALASI RADIOLOGI (Futri Nadia Vuspita, 2024)
SEGMENTASI CITRA CT SCAN PARU-PARU MENGGUNAKAN METODE DETEKSI TEPI UNTUK MENENTUKAN LUAS AREA KANKER (Munzir, 2020)
ISOLASI ASPERGILLUS SPP PADA PARU-PARU ITIK (ANASDOMESTICUS) DAN ENTOK (CAIRINAMOSCHATA) (LUCKY PRABOWO, 2021)
PENGUKURAN DIAMETER ABDOMEN PASIEN DEWASA TERHADAP ARUS TABUNG DENGAN METODE COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) MENGGUNAKAN PESAWAT CT-SCAN (PUTRI SAFIRA, 2018)
ANALISIS DISTRIBUSI DOSIS RADIASI FOTON PADA TREATMENT PLANNING SYSTEM (TPS) MENGGUNAKAN TEKNIK THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY (3D-CRT) UNTUK PENANGANAN KANKER PARU-PARU (Ariana Shafira Dewi, 2025)