Sistem pendinginan evaporatif tidak langsung siklus Maisotsenko (M-Cycle) dikenal memiliki efisiensi energi yang tinggi, khususnya di iklim kering. Namun, efektivitasnya di daerah tropis dengan kelembaban tinggi masih menjadi pertanyaan. Penelitian ini menganalisis unjuk kerja pendinginan siklus Maisotsenko ketika diterapkan di daerah tropis yang memiliki suhu tinggi dan kelembaban relatif yang bervariasi. Metodologi yang digunakan melibatkan pemodelan matematis dan simulasi numerik untuk mengevaluasi temperatur yang dihasilkan. Hasil penelitian menunjukkan bahwa meskipun siklus Maisotsenko mampu menurunkan suhu udara, kelembaban relatif udara yang dihasilkan cenderung meningkat dan suhu bola basah udara masuk yang tinggi menjadi pembatas utama untuk mencapai suhu kenyamanan termal yang ideal di iklim tropis. Meskipun demikian, temuan ini memperlihatkan potensi efisiensi energi yang substansi dan pengurangan emisi gas rumah kaca jika teknologi ini diterapkan secara luas di wilayah tropis, menjadikannya alternatif yang menarik untuk kebutuhan pendinginan berkelanjutan.
The Maisotsenko cycle (M-Cycle) indirect evaporative cooling system is known for its high energy efficiency, particularly in dry climates. However, its effectiveness in high-humidity tropical regions remains a question. This research analyzes the cooling performance of the Maisotsenko cycle when applied in tropical areas characterized by high temperatures and varying relative humidity. The methodology involves mathematical modeling and numerical simulation to evaluate the resulting temperatures. The study's findings indicate that although the Maisotsenko cycle can lower air temperature, the relative humidity of the cooled air tends to increase, and the high wet-bulb temperature of the inlet air becomes a primary limitation in achieving ideal thermal comfort temperatures in tropical climates. Nevertheless, these findings demonstrate substantial energy efficiency potential and greenhouse gas emission reduction if this technology is widely implemented in tropical regions, making it an attractive alternative for sustainable cooling needs.
KAJI EKSPERIMENTAL UNJUK KERJA SISTEM PENDINGIN SIKLUS MAISOTSENKO DENGAN MODIFIKASI SISTEM DESICCANT UNTUK APLIKASI DI IKLIM TROPIS (Haiqal Irfansyah, 2025)
KAJI EKSPERIMENTAL PENGARUH VARIASI LAJU ALIRAN TERHADAP UNJUK KERJA EARTH-AIR HEAT EXCHANGER (EAHE) PADA RUMAH TIPE 36 (ASY SYIFA MASTURA, 2025)
KAJI EKSPERIMENTAL KENYAMANAN TERMAL RUMAH TIPE 36 DENGAN PERBANDINGAN VENTILASI ALAMIAH DAN EAHE (EARTH-AIR HEAT EXCHANGER) (RIZKY KURNIAWAN, 2026)
IDENTIFIKASI KENYAMANAN TERMAL PADA BANGUNAN KOMERSIL (STUDI KASUS : WEDRINK ULEE LHEUE, BANDA ACEH) (ALFA ULIMI, 2025)
KAJI TEORITIS UNJUK KERJA TURBIN VENTILATOR UNTUK APLIKASI PENDINGIN RUMAH TIPE – 36 DENGAN SIMULASI CFD (Rizky, 2025)