Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
PENGEMBANGAN IMPLAN CRANIOPLASTY BERBAHAN ACRYLIC CEMENT BONE MENGGUNAKAN METODE ELEMEN HINGGA DAN METODE CETAK TEKAN
Pengarang
Afrizaldi pratama - Personal Name;
Dosen Pembimbing
Mohd. Iqbal - 196706081994031003 - Dosen Pembimbing I
M. Dirhamsyah - 196210021988111001 - Dosen Pembimbing II
Suhaeri - 196007151990021001 - Penguji
Rudi Kurniawan - 197910132003121002 - Penguji
Nomor Pokok Mahasiswa
1804102010077
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik., 2025
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Cranioplasty adalah prosedur bedah rekontruksi yang dilakukan untuk memperbaiki atau mengganti bagian tengkorak yang rusak atau hilang. Dalam beberapa tahun terakhir, teknologi implan telah berkembang, memungkinkan penggunaan bahan sintetik yang lebih efektif dan aman untuk merekonstruksi tulang tengkorak. Pada penelitian ini, akan dikembangkan cetakan untuk pembuatan implan cranioplasty dengan metode cetak tekan. Bentuk dan ukuran cetakan disesuaikan dengan implan cranioplasty yang dibuat. Desain implant cranioplasty yang akan dibuat diperoleh dari hasil Computerized Tomography Scan (CT-Scan). Selanjutntya, hasil CT-Scan yang diperoleh akan di ubah ke dalam format CAD dengan proses volume rendering, segmentasi, dan 3D modelling. Analisis FEM atau Metode Elemen Hingga dilakukan terhadap implant cranioplasty untuk mendapatkan nilai tegangan, displacement, dan regangan yang terjadi serta titik kritis setelah dilakukan pembebanan. Pembuatan cetakan metode cetak tekan untuk implant cranioplasty dilakukan dengan proses 3D Print menggunakan bahan Polylactic Acid (PLA). Setelah dilakukan pengambilan data simulasi, didapatkan nilai tegangan, displacement, dan regangan implant cranioplasty pada pembebanan 2.000 N sebesar 8,61 MPa, 0,20 mm, dan 0,0072011, pada pembebanan 5.000 N sebesar 21,53 MPa, 0,51 mm, dan 0,0180027, dan pada pembebanan 8.000 N sebesar 34,46 MPa, 0,82 mm, dan 0,0288044.
Cranioplasty is a reconstructive surgical procedure performed to repair or replace damaged or missing parts of the skull. In recent years, implant technology has advanced, allowing the use of more effective and safer synthetic materials to reconstruct skull bones. In this research, a mold will be developed for making cranioplasty implants using the press molding method. The shape and size of the mold are adjusted to the cranioplasty implant being made. The design of the cranioplasty implant that will be made is obtained from the results of a Computerized Tomography Scan (CT-Scan). Next, the CT-Scan results obtained will be converted into CAD format using volume rendering, segmentation and 3D modeling processes. FEM analysis or Finite Element Method was carried out on cranioplasty implants to obtain the stress, displacement and strain values that occurred as well as the critical point after loading. The press molding method for cranioplasty implants is made using a 3D Printing process using Polylactic Acid (PLA) material. After taking the simulation data, the stress, displacement and strain values of cranioplasty implants at a loading of 2000 N were 8.61 MPa, 0.20 mm and 0.0072011, and at a loading of 5000 N they were 21.53 MPa, 0.51 mm. , and 0.0180027, and at a load of 8000 N equal to 34.46 MPa, 0.82 mm, and 0.0288044.
LEVEL BLOOD UREA NITROGEN (BUN) DAN KREATININ MERPATI (COLUMBIA LIVIA) SELAMA KESEMBUHAN FRAKTUR HUMERUS YANG DIIMPLAN BONE PIN ALTERNATIF (ASNITA PURNAMA, 2021)
KADAR LEUKOSIT MERPATI SELAMA PROSES KESEMBUHAN FRAKTUR MENGGUNAKAN FIKSASI INTERNAL TULANG BIAWAK (REZA FADLY GINTING, 2021)
KADAR BLOOD UREA NITROGEN (BUN) DAN KREATININ KELINCI SETELAH DIIMPLAN BONE GRAFT HIDROKSIAPATIT CANGKANG (FARID IKRAM KAMIL, 2022)
PENGARUH VARIASI KOMPOSISI HAP-KITOSAN PADA BIOKOMPOSIT SEBAGAI KANDIDAT BONE GRAFT (LIDYA RIZQI PUTRI, 2021)
NILAI SERUM GLUTAMIC OXALOACETIC TRANSAMINASE (SGOT) DAN SERUM GLUTAMIC PYRUVIC TRANSAMINASE (SGPT) KELINCI SETELAH IMPLAN PLATE BERBAHAN LOGAM (Anta Rezky Sitepu, 2019)