KAJI EKSPERIMENTAL UNJUK KERJA AC DENGAN DAN TANPA DESUPERHEATER
Pengarang
Berlian Pagar Alam - Personal Name;
Dosen Pembimbing
Sarwo Edhy S - 198106262006041005 - Dosen Pembimbing I
Nomor Pokok Mahasiswa
1904102010093
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik., 2024
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Umumnya air conditioner (AC) melepaskan kalor dari kondensor,kalor ini tidak banyak dimanfaatkan dan dianggap sebagai kalor atau panas terbuang. Panas buangan ini dapat dimanfaatkan agar tidak terbuang sia-sia dan tidak menimbulkan kenaikan suhu global. Salah satu pemanfaatan panas buang pada AC adalah dengan menambahkan water heater yang terpasang dengan AC. Pemanfaatan ini dapat digunakan untuk keperluan sehari-hari, seperti air hangat untuk mandi. Penelitian ini berfokus pada unjuk kerja AC dengan penambahan desuperheater pada variasi suhu 18°C, 20°C, 22°C, dan 24°C. Hasil yang diperoleh dibandingkan dengan unjuk kerja AC tanpa desuperheater dengan variasi suhu yang sama. Pengujian AC tanpa desuperheater menghasilkan nilai COP tertinggi pada 5 menit pertama pengujian, yaitu pada suhu 24°C dengan nilai COP 4.45 Kwh, sedangkan nilai terendah terjadi pada suhu 18°C dengan COP 2.68 Kwh. Sebaliknya, Pengujian AC dengan desuperheater menghasilkan nilai COP tertinggi pada suhu 24°C sebesar 6.25 Kwh dan nilai terendah pada suhu 18°C sebesar 5.50 Kwh. Hasil perbandingan menunjukkan nilai COP dengan desuperheater lebih besar dikarenakan adanya proses perpindahan kalor dari coil ke air sehingga proses kerja pada kondensor juga berkurang.
Generally, air conditioners (AC) release heat from the condenser, which is not extensively utilized and is considered waste heat. This waste heat can be harnessed to prevent it from being wasted and to mitigate global temperature rise. One way to utilize the waste heat from an AC is by adding a water heater connected to the AC. This utilization can be used for everyday needs, such as providing warm water for bathing. This research focuses on the performance of an AC with the addition of a desuperheater at temperature variations of 18°C, 20°C, 22°C, and 24°C. The results are compared with the performance of an AC without a desuperheater at the same temperature variations. Testing the AC without a desuperheater yielded the highest COP value during the first 5 minutes of testing, which was at 24°C with a COP value of 4.45 kWh, while the lowest value occurred at 18°C with a COP of 2.68 kWh. Conversely, testing the AC with a desuperheater resulted in the highest COP value at 24°C of 6.25 kWh and the lowest value at 18°C of 5.50 kWh. The comparison results show that the COP value with the desuperheater is higher due to the heat transfer process from the coil to the water, thereby reducing the workload on the condenser.
ANALISA UNJUK KERJA MESIN DIESEL SATU SILINDER RUGGERINI HT-51 MENGGUNAKAN CAMPURAN MINYAK KELAPA SAWIT DAN SOLAR (Kamaruzzaman, 2024)
KESEIMBANGAN ENERGI PADA MESIN DIESEL RUGGERINI TIPE HT-51 DENGAN MENGGUNAKAN CAMPURAN MINYAK KELAPA SAWIT DAN SOLAR (Akhmad sholeh, 2024)
EVALUASI UNJUK KERJA AIR HEATING UNIT PADA GUDANG PENYIMPAN UREA CURAH PT. PUPUK ISKANDAR MUDA (Heri Setiawan, 2024)
ANALISA TEORTIS PERANCANGAN DAN UNJUK KERJA MESIN EKSTRUSI TERHADAP LAJU PRODUKSI PENCETAKAN BATU BATA (Mohammad Iqbal, 2024)
KAJI UNJUK KERJA KOMPRESOR PADA UNIT BOIL-OFF GAS PT. ARUN, NGL (MUHAMMAD YUSUF, 2025)