Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
ANALISIS PENGARUH HARMONISA TERHADAP ARUS NETRAL DAN RUGI-RUGI PADA TRANSFORMATOR DISTRIBUSI
Pengarang
FATHUR RAHMAN RAHBY - Personal Name;
Dosen Pembimbing
Rakhmad Syafutra Lubis - 196901051999031001 - Dosen Pembimbing I
Mahdi Syukri - 196812101998021001 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
1704105010006
Fakultas & Prodi
Fakultas Teknik / Teknik Elektro (S1) / PDDIKTI : 20201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik Elektro dan Komputer., 2024
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Perkembangan dunia teknologi informasi seperti komputer dan printer yang sangat dibutuhkan sehari-hari. Di lain sisi, keterbatasan energi menjadi penyebab peningkatan pemakaian LHE (Lampu Hemat Eenergi). LHE, printer dan komputer adalah beban nonlinier yang memicu harmonik sehingga menghambat kinerja sistem distribusi tenaga listrik, salah satunya Trafo distribusi. Melalui penakaran pada transformator distribusi dapat dilihat bahwa pada transformator distribusi dapat menimbulkan arus harmonik yang akan menaikkan rugi-rugi pada transformator distribusi sehingga dapat berpengaruh berkurangnya derating transformator (kapasitas transformator). Tingkatan harmonisa yang disetujui akan berguna untuk mengetahui transformator distribusi dapat dioperasikan dalam waktu lama tanpa menambahkan terlalu banyak elemen penyaring. Melalui proses pengambilan data serta metode analisa diketahui THD arus di Transformator ULP Syiah Kuala pada waktu tertentu ada yang melampaui tolak ukur. Sedangkan pada THD tekanannya tidak melampaui tolak ukur. Dapat diketahui, Semakin tinggi arus THD yang terdapat pada trafo, maka rugi-rugi pada trafo semakin besar, sehingga derating trafo juga akan semakin tinggi. Dengan demikian besarnya arus netral bergantung pada besarnya komponen harmonik ganjil dengan kelipatan 3, sehingga terlihat bahwa harmonik paling banyak terbesar pada arus netral.
Kata Kunci: trafo distribusi, arus netral, beban nonlinier, THD, derating trafo, rugi- rugi, harmonisa
The development of the world of information technology such as computers and printers which are needed every day. On the other hand, energy limitations are the cause of increasing use of LHE (Energy Saving Lamps). LHE, printers and computers are nonlinear loads that trigger harmonics, thereby hampering the performance of the electric power distribution system, one of which is the distribution transformer. By measuring the distribution transformer, it can be seen that the distribution transformer can cause harmonic currents which will increase losses in the distribution transformer so that it can have the effect of reducing transformer derating (transformer capacity). An approved harmonic level will be useful to know that the distribution transformer can be operated for a long time without adding too many filter elements. Through the data collection process and analysis methods, it is known that the current THD in the Syiah Kuala ULP Transformer at certain times exceeds the benchmark. Meanwhile, at THD the pressure does not exceed the benchmark. It can be seen that the higher the THD current in the transformer, the greater the losses in the transformer, so the derating of the transformer will also be higher. Thus, the magnitude of the neutral current depends on the magnitude of the odd harmonic component in multiples of 3, so it can be seen that the harmonics are the largest in the neutral current. Keyword: distribution transformers, neutral current, nonlinear loads, THD, transformer derating, losses, harmonics
ANALISIS PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES PADA TRANSFORMATOR DISTRIBUSI 200 KVA DI IFRC BANDA ACEH (Eddy Azhar, 2023)
ANALISIS PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES PADA TRANSFORMATOR DISTRIBUSI 200 KVA DI IFRC BANDA ACEH (Eddy Azhar, 2023)
ANALISIS PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES PADA TRANSFORMATOR DISTRIBUSI 200 KVA DI IFRC BANDA ACEH (Eddy Azhar, 2023)
ANALISIS PENGARUH ARUS NETRAL AKIBAT KETIDAKSEIMBANGAN BEBAN PADA TRANSFORMATOR DISTRIBUSI 3 FASA 20 KV (SITI RADHIYA SALIM, 2022)
ANALISIS RUGI-RUGI DAYA PADA TRANSFORMATOR AKIBAT DISTORSI HARMONIK (MUNANDAR, 2024)