Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
ANALISIS KUALITAS TAHANAN ISOLASI TRANSFORMATOR DISTRIBUSI MENGGUNAKAN METODE INDEKS POLARISASI DI PT. PLN (PERSERO) UP3 SIGLI
Pengarang
Ghina Inayati - Personal Name;
Dosen Pembimbing
Mahdi Syukri - 196812101998021001 - Dosen Pembimbing I
Ramdhan Halid Siregar - 196909201999031001 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
2004105010006
Fakultas & Prodi
Fakultas Teknik / Teknik Elektro (S1) / PDDIKTI : 20201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik Elektro., 2024
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Transformator distribusi memiliki bagian utama salah satunya yaitu lilitan primer dan sekunder. Lilitan ini dilindungi oleh isolasi supaya tidak terjadinya kebocoran arus ketika beroperasi. Salah satu pengujian yang dapat dilakukan untuk mengetahui kualitas isolasi adalah pengujian tahanan isolasi menggunakan metode indeks polarisasi. Namun sejauh ini nilai indeks polarisasi tidak diketahui, oleh karena itu dilakukan pengujian menggunakan motode ini untuk memastikan apakah transformator layak atau tidak untuk di operasikan. Penelitian ini dilakukan untuk menganalisis kualitas tahanan isolasi transformator distribusi di PT. PLN (PERSERO) UP3 Sigli guna memastikan keandalan dan kinerja sistem distribusi tenaga listrik. Metode penelitian yang digunakan menggunakan metode indeks polarisasi. Metode pengujian ini menghasilkan nilai polarisasi, yang digunakan untuk mengevaluasi kualitas tahanan isolasi transformator distribusi. Hasil pengukuran tahanan isolasi transformator ini menunjukkan kemampuan isolasi transformator untuk mengisi kapasitansi tinggi dan kondisi bersih serta kering dari isolasi. Berdasarkan standar IEEE 43-2000 suatu transformator distribusi dapat dikatakan kulitas tahanan isolasinya dalam kondisi baik nilai indeks polarisasinya yaitu >1.25 namun jika nilai indeks polarisasinya 1.25 sedangkan dua transformator lainnya memiliki kualitas tahanan isolasi yang buruk karena nilai indeks polarisasinya
Distribution transformers have main parts, one of which is the primary and secondary windings. These windings are protected by insulation so that there is no current leakage when operating. One of the tests that can be carried out to determine the quality of insulation is the insulation resistance test using the polarization index method. However, so far the polarization index value is unknown, therefore testing is carried out using this method to ensure whether the transformer is suitable for operation or not. This study was conducted to analyze the quality of the insulation resistance of distribution transformers at PT. PLN (PERSERO) UP3 Sigli to ensure the reliability and performance of the electric power distribution system. The research method used uses the polarization index method. This test method produces a polarization value, which is used to evaluate the quality of the insulation resistance of distribution transformers. The results of measuring the insulation resistance of this transformer indicate the ability of the transformer insulation to charge high capacitance and the clean and dry conditions of the insulation. Based on the IEEE 43-2000 standard, a distribution transformer can be said to have good insulation resistance quality, the polarization index value is >1.25, but if the polarization index value is 1.25 while the other two transformers had poor insulation resistance quality because its polarization index value was
MITIGASI HARMONIK MENGGUNAKAN TRANSFORMATOR ZIG-ZAG PADA TRANSFORMATOR DISTRIBUSI DI PT. PLN ULP SYIAH KUALA (Ichsan Muhadis Lubis, 2023)
PEMELIHARAAN TRANSFORMATOR DISTRIBUSI UNTUK PENCEGAHAN KERUSAKAN AKIBAT BEBAN OVERLOAD DI PT. PLN (PERSERO) ULP JEURAM (Zulfarizal Saifnur, 2022)
PEMELIHARAAN TRANSFORMATOR 20 KV PADA PT. PLN (PERSERO) ULP TAPAKTUAN (Lisa Suriani, 2021)
SIMULASI MITIGASI HARMONISA STUDI KASUS PADA TRANSFORMATOR DISTRIBUSI PT. PLN (PERSERO) ULP SYIAH KUALA (Faisal, 2023)
STUDI PENGGUNAAN DAN PENGUJIAN MINYAK ISOLASI PADA TRANSFORMATOR DAYA DI GARDU INDUK (GI) P3B SUMATERA UPT BANDA ACEH (Januar Subhi, 2014)