PT. PLN UPT Banda Aceh merupakan perusahaan listrik yang bergerak di bidang penyaluran atau distribusi sistem tenaga listrik 20 kV di area Banda Aceh. Pada saluran distribusi sering kali dijumpai berbagai macam gangguan salah satunya adalah gangguan hubung singkat. Gangguan hubung singkat ini dapat menimbulkan arus gangguan yang terjadi dalam waktu yang singkat dan dapat mengakibatkan penurunan tegangan sesaat atau dikenal dengan kedip tegangan. Pada saluran distribusi gangguan hubung singkat yang sering terjadi adalah hubung singkat 1 fasa ke tanah, 2 fasa, dan 3 fasa. Agar nilai kedip tegangan pada saluran akibat hubung singkat dapat diketahui perlu dilakukan analisis nilai arus gangguan hubuang singkat dan kedip tegangan dengan mengasumsikan titikgangguan berada pada 25%, 50%, 75%, dan 100 % dari keseluruhan panjang Penyulang BA 15.. Kedip tegangan saat terjadi hubung singkat 1 fasa ke tanah pada titik 25%, 50%, 75%, dan 100 % secara berturut-turut adalah; 8663,68∠0V, 5773,4∠0 V, 2886,87∠0 V, dan 525,48∠0 V. Kedip tegangan saat terjadi gangguan hubung singkat 2 fasa adalah; 19022,602∠0 V, 16637,035∠0 V, 12106,47∠0 V, 11826,98∠0 V. sedangkan pada kedip tegangan ganggauan akibat hubung singkat 3 fasa adalah; 5000∠-76,05 V, 10000∠-70,21 V, 15000∠67.05 V, 18231,99∠24,29 V. Gangguan kedip tegangan ini dapat diperbaiki dengan menggunakan alat DVR yang dapat menginjeksi tegangan yang dibutuhkan .
Kata Kunci; Hubung Singkat, Kedip Tegangan, DVR , PT. PLN UPT Banda Aceh.
t
PT. PLN UPT Banda Aceh is an electricity company engaged in the distribution or distribution of 20 kV electric power systems in the Banda Aceh area. In distribution line, various kinds of disturbances are often found, one of which is short circuit interference. This short-circuit fault can cause a disturbance current that occurs in a short period of time and can result in a momentary voltage sag. In the distribution line, the short-circuit disturbances that often occur are 1-phase short-circuits to the ground, 2-phase, and 3-phase. In order for the value of voltage sag in the line due to short circuit to be known, it is necessary to perform an analysis of the calculation of the current of the fault of the short circuit and the voltage sag by assuming that the fault point is at 25%, 50%, 75%, and 100% of the overall length of the BA 15 feeder.. Voltage sag when there is a 1-phase short circuit to the ground at 25%, 50%, 75%, and 100 % respectively are; 8663,68∠0V, 5773,4∠0 V, 2886,87∠0 V, dan 525,48∠0 V. Voltage sag during a 2-phase short circuit disturbance is; 19022,602∠0 V, 16637,035∠0 V, 12106,47∠0 V, 11826,98∠0 V. while in the disturbance voltage sag due to the 3-phase short circuit is; 5000∠-76,05 V, 10000∠-70,21 V, 15000∠67.05 V, 18231,99∠24,29 V. The voltage sags interference can be corrected by using a DVR tool that can inject the required voltage. Keywords: Short circuit, voltage sag, DVR, PT. PLN UPT Banda Aceh.
ANALISA KEDIP TEGANGAN PADA SISTEM DISTRIBUSI 20 KV AKIBAT ARUS HUBUNG SINGKAT DI BANDAR UDARA SULTAN ISKANDAR MUDA ACEH (Ryan Firdaus, 2014)
ANALISA GANGGUAN HUBUNG SINGKAT TERHADAP KEDIP TEGANGAN PADA SISTEM DISTRIBUSI 20 KV PENYULANG KHUSUS BANDAR UDARA SULTAN ISKANDAR MUDA BANDA ACEH (Ari Fadhilah, 2024)
ANALISIS GANGGUAN HUBUNG SINGKAT PADA SALURAN KABEL TEGANGAN MENENGAH 20 KV STUDI KASUS PADA PENYULANG ULEE KARENG MENGGUNAKAN APLIKASI ETAP (MUHAMMAD RIDHO, 2025)
PENGGUNAAN PEMBATAS ARUS HUBUNG SINGKAT DENGAN REAKTOR SERI JARINGAN DISTRIBUSI 20KV GARDU HUBUNG ULEE KARENG (ALWAN FARRAS, 2021)
ANALISIS DAMPAK TERPUTUSNYA KAWAT NETRAL PADA RNTRANSFORMATOR DISTRIBUSI 200 KVA, 20 KV/ 380 VRNDI GARDU JL. T. ISKANDAR SP. BEURAWE SHOPPING CENTER (Joni Rahmad, 2024)