Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
PENGARUH DIAMETER EFEKTIF TERHADAP SIZE SPECIFIC DOSE ESTIMATE (SSDE) PADA PEMERIKSAAN CT-SCAN ABDOMEN DI RUMAH SAKIT UMUM DAERAH DR. ZAINOEL ABIDIN BANDA ACEH
Pengarang
Cintya Ikramina Tobing - Personal Name;
Dosen Pembimbing
Rini Safitri - 197004251995122001 - Dosen Pembimbing I
Evi Yufita - 197509202000122001 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
1908102010025
Fakultas & Prodi
Fakultas MIPA / Fisika (S1) / PDDIKTI : 45201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas MIPA Fisika., 2024
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Computed Tomography Scanning (CT-Scan) merupakan salah satu peralatan medis yang digunakan untuk menegakkan diagnosea dengan pemanfaatan sinar-X. Salah satu pemeriksaan yang sering dilakukan yaitu pemeriksaan CT-Scan bagian perut. Pada area perut terdapat banyak organ yang sangat sensitif terhadap radiasi utamanya organ reproduksi. Selama ini dosis CT-Scan dinyatakan dalam besaran CTDIvol padahal metrik tersebut hanya untuk menunjukkan output (keluaran) radiasi CT-Scan bukan menunjukkan dosis yang sampai ke pasien. Penelitian ini bertujuan untuk mengetahui pengaruh antara diameter efektif dengan Size Specific Dose Estimate (SSDE) dan mengetahui pengaruh antara faktor-faktor lain, seperti berat badan, usia, dan parameter CT-Scan dengan SSDE pada pemeriksaan CT-Scan abdomen di Rumah Sakit Umum Daerah dr. Zainoel Abidin Banda Aceh. Metode Size Specific Dose Estimate (SSDE) adalah metode yang dikeluarkan oleh AAPM tahun 2011 untuk estimasi dosis dengan mempertimbangkan faktor geometri tubuh pasien tersebut. Data yang digunakan berupa inisial pasien, berat badan, usia, CTDIvol, DLP, dan diameter AP dan LAT pada citra pasien CT-Scan abdomen. Hasil penelitian ini menunjukkan diameter efektif pada pemeriksaan CT-Scan bagian abdomen memiliki pengaruh linear yang sangat lemah terhadap SSDE, dimana koefisien korelasinya sebesar -0,1047 dan berat badan memiliki pengaruh linear yang sangat lemah terhadap SSDE, dimana koefisien korelasinya sebesar -0,297; sedangkan usia tidak terjadi pengaruh yang signifikan terhadap SSDE, dimana koefisien korelasinya sebesar -0,00259; serta arus waktu memiliki pengaruh linear yang sangat lemah, dimana koefisien korelasinya sebesar 0,281.
Kata kunci: SSDE, Dosis Efektif, CT-Scan perut, CTDIvol, dan DLP
Computed Tomography Scanning (CT-Scan) is a type of medical equipment used to confirm a diagnosis using X-rays. One of the examinations that is often carried out is a CT-Scan examination of the abdomen. In the abdominal area there are many organs that are very sensitive to radiation, especially the reproductive organs. So far, the CT-Scan dose is expressed in terms of CTDIvol, even though this metric only shows the output of CT-Scan radiation, not the dose that reaches the patient. This study aims to determine the relationship between effective diameter and Size Specific Dose Estimate (SSDE) and determine the relationship between other factors, such as body weight, age, and CT-Scan parameters with SSDE on abdominal CT-Scan examinations at Regional General Hospitals. Dr. Zainoel Abidin Banda Aceh. The Size Specific Dose Estimate (SSDE) method is a method issued by AAPM in 2011 to estimate dose by considering the patient's body geometry. The data used are the patient's initials, body weight, age, CTDIvol, DLP, and AP and LAT diameters on the patient's abdominal CT-Scan image. The results of this study show that the effective diameter on an abdominal CT-Scan examination has a very weak linear influence on SSDE, where the correlation coefficient is -0.1047 and body weight has a very weak linear influence on SSDE, where the correlation coefficient is -0.297; while age does not have a significant effect on SSDE, where the correlation coefficient is -0.00259; and the flow of time has a very weak linear influence, where the correlation coefficient is 0.281. Keywords: SSDE, Effective Dose, CT-Scan abdomen, CTDIvol, and DLP
PENGUKURAN ENTRANCE SURFACE DOSE (ESD) TERHADAP RADIASI PESAWAT CT-SCAN PADA PEMERIKSAAN ABDOMEN DI RSUDZA BANDA ACEH (Nur Ulia Putri, 2022)
PENGUKURAN DIAMETER ABDOMEN PASIEN DEWASA TERHADAP ARUS TABUNG DENGAN METODE COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) MENGGUNAKAN PESAWAT CT-SCAN (PUTRI SAFIRA, 2018)
PENGARUH SKOR CT SCAN HELSINKI DAN NILAI RASIO NEUTROFIL-LIMFOSIT TERHADAP LUARAN PASIEN CEDERA KEPALA (dr. Muhammad Ansari Adista, 2021)
PENGARUH EMOSIONAL PEKERJA TERHADAP KINERJA; PENYAMPAIAN AFEKTIF SEBAGAI VARIABEL PEMEDIASI PADA PERAWAT RUMAH SAKIT UMUM DAERAH DR ZAINOEL ABIDIN BANDA ACEH (YUNI ANANDA ZULFIDA, 2016)
STUDI PENGARUH FAKTOR EKSPOSI, PANJANG SCAN, DAN PITCH TERHADAP DOSIS EFEKTIF PADA PEMERIKSAAN CT SCAN ABDOMEN KONTRAS (FAUZAN ABRARI, 2023)