ANALISIS PENGARUH FLUID VISCOUS DAMPER PADA STRUKTUR BANGUNAN SEKOLAH DENGAN PEMBEBANAN SEISMIK
Pengarang
Jihan Nabila - Personal Name;
Dosen Pembimbing
Zahra Amalia - 199203122019032023 - Dosen Pembimbing I
Rudiansyah Putra - 197509232002121004 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
2004101010090
Fakultas & Prodi
Fakultas Teknik / Teknik Sipil (S1) / PDDIKTI : 22201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik Sipil., 2024
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Sejarah gempa yang terjadi di Aceh menyebabkan Aceh membutuhkan struktur bangunan tahan gempa. Hal tersebut dilakukan untuk mengurangi dampak kerusakan dan korban jiwa akibat rusaknya infrastruktur. Salah satu bangunan yang mengalami dampak kerusakan saat gempa terjadi ialah bangunan sekolah. Pemerintah telah menetapkan Petunjuk Teknis Standarisasi Desain dan Penilaian Kerusakan Sekolah dan Madrasah pada tahun 2020. Namun, desain sekolah dan madrasah pada petunjuk teknis tersebut perlu dievaluasi responnya terhadap beban seismik di wilayah Aceh. Berdasarkan hasil perhitungan awal, dengan pemberian beban gempa respon spektrum wilayah Aceh menunjukkan bahwa bangunan sekolah yang di desain berdasarkan petunjuk tersebut memiliki simpangan antar tingkat diluar batas izin pada SNI 1726:2019. Sehingga diperlukan perkuatan struktur dengan menambahkan fluid viscous damper pada struktur. Oleh karena itu, penelitian ini dilakukan untuk mengetahui efektivitas penggunaan fluid viscous damper terhadap respon bangunan sekolah dengan pemberian beban seismik. Penelitian ini memodelkan struktur bangunan sekolah tanpa fluid viscous damper dan bangunan sekolah menggunakan fluid viscous damper dengan 4 pola pemasangan yang berbeda saat diberikan beban seismik. Pemodelan dan analisis pada penelitian ini dilakukan menggunakan software SAP2000. Hasil dari penelitian ini menunjukkan bahwa penggunaan fluid viscous damper pada struktur bangunan sekolah mempengaruhi respon bangunan. Pola 4 merupakan pola yang paling baik dalam mereduksi beban seismik dalam dua arah dengan menurunkan nilai base shear, displacement dan simpangan antar tingkat dari struktur.
The history of earthquakes that occurred in Aceh causes Aceh to need earthquake-resistant building structures. This was done to reduce the impact of damage and loss of life due to damaged infrastructure. One of the buildings that experienced damage when the earthquake occurred is the school building. The government has established Technical Guidelines for Standardization of Design and Damage Assessment of Schools and Madrasah in 2020. However, school and madrasah designs in these technical instructions need to be evaluated for their response to seismic loads in the Aceh region. Based on the results of preliminary calculations, by providing the earthquake load response spectrum for the Aceh region, it shows that the school building designed based on these instructions has deviations between levels outside the permit limits in SNI 1726:2019. So it is necessary to strengthen the structure by adding fluid viscous damper on structure. Therefore, this research was conducted to determine the effectiveness of use fluid viscous damper on the response of school buildings to seismic loads. This research models the structure of a school building without fluid viscous damper and school buildings use fluid viscous damper with 4 different installation patterns when given seismic loads. Modeling and analysis in this research was carried out using software SAP2000. The results of this study show that the use of fluid viscous damper the structure of the school building influences the response of the building. Pattern 4 is the best pattern in reducing seismic loads in two directions by reducing the value base shear, displacement and deviations between levels of the structure.
PENGARUH PEMODELAN POLA PEMASANGAN FLUID VISCOUS DAMPER TERHADAP PERFORMA SEISMIK BANGUNAN SEKOLAH MENGGUNAKAN NLTHA (ANGGIESKA SALSABILA GINTING, 2025)
EVALUASI KINERJA SEISMIK PADA TIPIKAL BANGUNAN SEKOLAH DI KOTA BANDA ACEH DENGAN PENGEMBANGAN KURVA KERAPUHAN BERBASIS INCREMENTAL DYNAMIC ANALYSIS (RIFQI IRVANSYAH, 2019)
PEMODELAN SOIL STRUCTURE INTERACTION TERHADAP RESPON SEISMIK BANGUNAN (Ratu Shara Faradiba, 2024)
STUDI PERKUATAN KAPASITAS BANGUNAN SEKOLAH DENGAN KONSTRUKSI BETON BERTULANG DI BANDA ACEH TERHADAP BAHAYA GEMPA DAN TSUNAMI (PUTRI ISTIQAMAH, 2021)
STUDI KERENTANAN STRUKTUR BANGUNAN TSUNAMI VERTICAL EVACUATION (TVE) BUILDINGS DENGAN METODE DESAIN BERBASIS KINERJA (Zu Irfan, 2023)