PENGARUH INTRUSI AIR ASIN TERHADAP UMUR BANGUNAN PELAYANAN PUBLIK DI ZONA TIMUR KOTA BANDA ACEH
Pengarang
Nazwa Ulrahmah - Personal Name;
Dosen Pembimbing
Surya Bermansyah - 197210022000031002 - Dosen Pembimbing I
Rijalul Fikri - 198601122022031001 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
2004101010074
Fakultas & Prodi
Fakultas Teknik / Teknik Sipil (S1) / PDDIKTI : 22201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik Sipil., 2024
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Tsunami yang terjadi di Kota Banda Aceh pada akhir tahun 2004 silam menyebabkan tercemarnya tanah yang disebabkan oleh intrusi air asin dan terendapnya lumpur berkadar garam tinggi di atas permukaan tanah. Intrusi air asin secara berulang ke dalam bangunan dapat menyebabkan kerusakan secara struktural dan degradasi material bangunan sehingga menyebabkan berkurangnya umur layan bangunan beton bertulang. Kerusakan akibat korosi pada bangunan pelayanan publik bisa menjadi masalah serius karena dapat mempengaruhi fungsi dan keamanan bangunan tersebut. Pengujian kuat tarik dan weight loss pada benda uji BjTP 280 Ø10 mm, serta BjTS 420 D13 mm dan D16 mm setelah direndam selama 60 hari. Dan pengujian kuat tekan dan uji karbonasi terhadap benda uji beton silinder FAS 0,5 dan 0,45 setelah direndam selama 90 hari. Hasil menunjukkan bahwa nilai salinitas mempengaruhi laju korosi pada baja tulangan, hal ini dapat dilihat dari nilai laju korosi lebih besar pada benda uji yang direndam di zona 2.1 (zona air payau). Nilai laju korosi pada zona 2.1 setelah benda uji di tanam selama 60 hari ialah sebesar 0,0940 mm/th untuk BjTP Ø10, 0,0853 mm/th untuk BjTS D13, dan 0,0865 mm/th untuk BjTS D16 sehingga ketahanan korosi dikategorikan relatif baik. Tidak hanya laju korosi, nilai salinitas juga mempengaruhi kuat tarik baja dan kuat tekan beton walaupun tidak signifikan. Kuat tarik baja dan kuat tekan benda uji yang berada pada salinitas air asin lebih rendah dibandingkan benda uji yang berada pada salinitas air payau dan tawar. Pada pengujian karbonasi, hanya pada bagian permukaan luar yang mengalami karbonasi. Prediksi umur bangunan Puskesmas Pembantu Kajhu yang berada pada zona 2.1 ialah 40-58 tahun terhitung sejak tahun 2004. Dengan demikian dapat disimpulkan bahwa semakin tinggi nilai salinitas maka semakin besar nilai laju korosinya dan semakin berkurang umur bangunannya.
Kata Kunci: salinitas, laju korosi, karbonasi, umur bangunan.
The tsunami that hit the city of Banda Aceh in late 2004 resulted in soil contamination caused by saltwater intrusion and the deposition of highly saline mud on the ground. Repeated saltwater intrusion into buildings can cause structural damage and degradation of building materials resulting in reduced service life of reinforced concrete buildings. Corrosion damage in public service buildings can be a serious problem as it can affect the function and safety of the building. Tensile strength and weight loss tests on BjTP 280 Ø10 mm, and BjTS 420 D13 mm and D16 mm specimens after soaking for 60 days. And compressive strength testing and carbonation testing of FAS 0.5 and 0.45 cylindrical concrete specimens after soaking for 90 days. The results show that the salinity value affects the corrosion rate of reinforcing steel, this can be seen from the greater corrosion rate value in the test specimens immersed in zone 2.1 (brackish water zone). The corrosion rate value in zone 2.1 after the test specimens were planted for 60 days was 0.0940 mm/year for BjTP Ø10, 0.0853 mm/year for BjTS D13, and 0.0865 mm/year for BjTS D16 so that the corrosion resistance was categorized as relatively good. Not only the corrosion rate, but the salinity value also affects the tensile strength of steel and the compressive strength of concrete even though it is not significant. The tensile strength of steel and compressive strength of test specimens in saltwater salinity are lower than those in brackish and freshwater salinity. In carbonation testing, only the outer surface is carbonated. Kajhu helpers in zone 2.1 have been 40-58 years old since 2004. Thus it can be concluded that the higher the salinity value, the greater the corrosion rate value and the less the building life. Keywords: Salinity, corrosion rate, carbonation, building life.
PENGARUH SALINITAS TERHADAP UMUR BANGUNAN RUMAH PENGEMBANG DI ZONA BARAT KRUENG LAMNYONG BERDASARKAN PEMETAAN INTRUSI AIR ASIN (DIMAS FACHRURRAZI, 2023)
PENGARUH INTRUSI AIR ASIN TERHADAP UMUR BANGUNAN PELAYANAN PUBLIK DI ZONA TIMUR KOTA BANDA ACEH (Nazwa Ulrahmah, 2024)
PENGARUH INTRUSI AIR ASIN TERHADAP PREDIKSI UMUR LAYAN BANGUNAN MASJID DI ZONA BARAT KOTA BANDA ACEH (Zahra Riva Irhammi, 2024)
PENAGRUH SALINITAS TERHADAP UMUR BANGUNAN RUMAH PRIBADI PADA ZONA TIMUR KRUENG ACEH BERDASARKAN PEMETAAN INTRUSI AIR ASIN (Teuku Muhammad Haikal, 2023)
PEMETAAN INTRUSI AIR ASIN DI ZONA TIMUR KOTA BANDA ACEH UNTUK PREDIKSI UMUR LAYAN BANGUNAN (Maghfiratun Husna, 2024)