ANALISIS KINERJA STRUKTUR GEDUNG DISPORA PROVINSI ACEH YANG BAJA TULANGAN KOLOMNYA MENGALAMI KOROSI
Pengarang
NAHDA NABILA - Personal Name;
Dosen Pembimbing
Muttaqin - 196606151990091001 - Dosen Pembimbing I
Zahra Amalia - 199203122019032023 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
2004101010116
Fakultas & Prodi
Fakultas Teknik / Teknik Sipil (S1) / PDDIKTI : 22201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik., 2024
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Gedung Dinas Pemuda dan Olahraga (Dispora) Provinsi Aceh yang berada di Kecamatan Kuta Alam, Kota Banda Aceh merupakan salah satu bangunan yang terdampak tsunami Aceh pada tahun 2004. Air laut yang memiliki sifat korosif tinggi menyebabkan baja tulangan pada struktur kolom bangunan ini mengalami korosi serta berakibat retak pada beton kolom. Pada penelitian ini ditinjau bagaimana kurva kapasitas struktur gedung Dispora Aceh dengan analisis pushover dan kinerja struktur berdasarkan kondisi awal dan eksisting berdasarkan metode ATC-40. Data yang digunakan pada penelitian ini diperoleh dari asesmen yang dilakukan oleh Tim Asesmen Laboratorium Forensik Struktur Bangunan Universitas Syiah Kuala dan Standar Nasional Indonesia (SNI). Pemodelan struktur dilakukan dengan menggunakan software SAP2000. Berdasarkan hasil analisis pushover arah X, pada kondisi awal gaya geser dasar maksimum yang mampu ditahan struktur adalah sebesar 5427,845 kN dengan displacement sebesar 0,113 dan pada kondisi eksisting gaya geser dasar maksimum yang mampu ditahan struktur adalah sebesar 3981,187 kN dengan displacement sebesar 0,0834 m. Pada hasil analisis pushover arah Y, pada kondisi awal gaya geser dasar maksimum yang mampu ditahan oleh struktur adalah 7206,760 kN dengan displacement sebesar 0,152 m dan pada kondisi eksisting gaya geser dasar maksimum yang mampu ditahan oleh struktur adalah 5904,312 kN dengan displacement sebesar 0,144 m. Level kinerja struktur baik dalam kondisi awal maupun eksisting masuk ke dalam kategori Immediate Occupancy (IO) yang berarti jika struktur mengalami gempa maka kapasitas struktur hampir sama sebelum gempa dan risiko cedera yang mengancam jiwa akibat kegagalan struktural sangat kecil serta bangunan masih aman untuk digunakan. Dari mekanisme sendi plastis pada saat step dengan gaya geser maksimum dapat diketahui bahwa proses keruntuhan struktur dimulai dari kolom terlebih dahulu.
The building of the Dinas Pemuda dan Olahraga (Dispora) of Aceh Province, located in the Kuta Alam District, Banda Aceh City, is one of the buildings affected by the Aceh tsunami in 2004. The corrosive characteristic of seawater has led to corrosion of the reinforcement steel in the column structure of this building, resulting in spalling of the column concrete. This study aims to examine the capacity curve of the building structure through pushover analysis and structural performance based on initial and existing conditions based on the ATC-40 method. The data used in this research were obtained from assessments conducted by the Tim Asesmen Laboratorium Forensik Struktur Bangunan Universitas Syiah Kuala and the Standar Nasional Indonesia (SNI). Structural modeling was performed using SAP2000 software. Based on the pushover analysis results in the X direction, in the initial condition the maximum base shear force that the structure can withstand is 5427,845 kN with a displacement of 0,113 m, and in the existing condition the maximum base shear force that the structure can withstand is 3981,187 kN with a displacement of 0,0834 m. In the pushover analysis results in the Y direction, in the initial condition, the maximum base shear force that the structure can withstand is 7206,760 kN with a displacement of 0,152 m, and in the existing condition, the maximum base shear force that the structure can withstand is 5904,312 kN with a displacement of 0,144 m. The structural performance level in both initial and existing conditions falls into the Immediate Occupancy (IO) category, meaning that if the structure experiences an earthquake, its capacity remains almost the same as before the earthquake, and the risk of life-threatening injuries due to structural failure is very low, and the building is still safe for occupancy. From the plastic hinge mechanism observed at the step with maximum shear force, it can be inferred that the structural collapse process initiates from the columns first.
ANALISIS KINERJA STRUKTUR GEDUNG DISPORA PROVINSI ACEH YANG BAJA TULANGAN KOLOMNYA MENGALAMI KOROSI (NAHDA NABILA, 2024)
ASSESSMENT, KINERJA, DAN PERKUATAN STRUKTUR GEDUNG PEMUDA (YOUTH CENTRE) ACEH AKIBAT KOROSI BAJA TULANGAN (Alfisyahrin, 2022)
ANALISA LAJU KOROSI ATMOSFERIK DI KAWASAN PEUKAN BADA ACEH BESAR DAN MEURAXA BANDA ACEH (Sudirman, 2023)
ANALISA PERLAKUAN BAJA TULANGAN TERHADAP KOROSI STRUKTUR BETON BERTULANG (Afwan Halim, 2024)
PEMETAAN INTRUSI AIR ASIN DI ZONA TIMUR KOTA BANDA ACEH UNTUK PREDIKSI UMUR LAYAN BANGUNAN (Maghfiratun Husna, 2024)