Menara pendingin (cooling tower) adalah suatu alat sistem pendingin yang sering digunakan industri sebagai alat penukar kalor yang berfungsi untuk mendinginkan air yang kontak langsung dengan udara. Hal ini mengakibatkan terjadinya penguapan sehingga terjadi jugalah penurunan temperatur air. Untuk itu, peneliti melakukan penelitian dengan studi eksperimental pengaruh dari jumlah lubang 80, 120, 185 dan 250 pada plat datar menara pendingin dengan variasi temperatur inlet yaitu 65℃, 75℃ dan 85℃. Penelitian ini bertujuan untuk mengetahui karakteristik perpindahan panas serta mengetahui pengaruh jumlah lubang dan variasi temperatur inlet terhadap kinerja menara pendingin bertingkat banyak. Dimensi tinggi keseluruhan menara pendingin yaitu sekitar 2,4 m dengan luas setiap plat datar 0,7 m × 0,5 m dan kemiringan susunan setiap plat adalah 15°. Hasil penelitian menunjukkan bahwa laju perpindahan panas paling tinggi terjadi ketika temperatur inlet 85℃ dan variasi jumlah lubang paling banyak yaitu 250 lubang. Nilai koefisien perpindahan panas yang paling besar terjadi ketika temperatur inlet 75℃ dengan variasi jumlah lubang plat tertinggi yaitu 250 lubang. Sehingga terdapat pengaruh yang besar antara jumlah lubang dengan tingginya nilai laju perpindahan panas, koefisien perpindahan panas konveksi serta selisih temperatur tertinggi pada keoptimalan kinerja menara pendingin.
Cooling tower is a cooling system tool that is often used by industry as a heat exchanger that functions to cool water in direct contact with air. This results in evaporation so that there is also a decrease in water temperature. For this reason, researchers conducted research with an experimental study of the effect of the number of holes 80, 120, 185 and 250 on the cooling tower flat plate with variations in inlet temperatures of 65, 75 and 85. This study aims to determine the heat transfer characteristics and determine the effect of the number of holes and inlet temperature variations on the performance of multi-storey cooling towers. The overall height dimension of the cooling tower is about 2.4 m with the area of each flat plate 0.7 m × 0.5 m and the slope of the arrangement of each plate is 15. The results showed that the highest heat transfer rate occurred when the inlet temperature was 85 and the most variation in the number of holes was 250 holes. The largest heat transfer coefficient value occurs when the inlet temperature is 75 with the highest variation in the number of plate holes, namely 250 holes. So there is a big influence between the number of holes with the high value of heat transfer rate, convection heat transfer coefficient and the highest temperature difference on the optimization of cooling tower performance.
KAJIAN KARAKTERISTIK PERPINDAHAN PANAS PADA MENARARNPENDINGIN TIPE PLAT DATAR BERTINGKAT AKIBAT PENGARUHRNLETAK LUBANG (AFDHALUL RAJAI, 2022)
KAJIAN EKSPERIMENTAL PENGARUH JUMLAH LUBANG PLAT TERHADAP PERPINDAHAN PANAS KONVEKSI PADA MENARA PENDINGIN TIPE PLAT DATAR (Asra Yufandi, 2021)
ANALISA PENGARUH JUMLAH LUBANG PADA MENARA PENDINGIN TIPE PLAT DATAR BERTINGKAT BANYAK TERHADAP KARAKTERISTIK PERPINDAHAN PANAS (ALIFIA KANEYSHA PERANGIN-ANGIN, 2024)
KAJIAN PERPINDAHAN PANAS PADA MENARA PENDINGIN (COOLING TOWER) TIPE PLAT DATAR BERLUBANG SEGITIGA (Fikri Aulia, 2023)
ANALISA PENGARUH KECEPATAN UDARA PADA MENARA PENDINGIN TIPE PLAT DATAR BERLUBANG BERTINGKAT BANYAK TERHADAP KARAKTERISTIK PERPINDAHAN PANAS (, 2024)