SKRIPSI
UJI KESESUAIAN GENERATOR DAN TABUNG PESAWAT SINAR-X DI LABORATORIUM KLINIK FAKULTAS KEDOKTERAN HEWAN UNIVERSITAS SYIAH KUALA
Pengarang
alya rizka maiza - Personal Name;
Dosen Pembimbing
Rini Safitri - 197004251995122001 - Dosen Pembimbing I
Malahayati - 197407252000122001 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
1908102010062
Fakultas & Prodi
Fakultas MIPA / Fisika (S1) / PDDIKTI : 45201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas mipa., 2023
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Pesawat sinar-X merupakan salah satu perangkat yang banyak tersedia di laboratorium kesehatan yang digunakan sebagai alat bantu untuk mendiagnosa penyakit. Fakultas Kedokteran Hewan, Universitas Syiah Kuala memiliki fasilitas ruang Laboratorium Klinik dengan pesawat sinar-X merk Siemens yang digunakan untuk keperluan diagnosa penyakit terutama pada hewan. Perangkat tersebut telah beroperasi selama 4 (empat) tahun dan belum pernah dilakukan uji kesesuaian dalam masa pengoperasiannya. Uji kesesuaian merupakan serangkaian kegiatan pengujian untuk memastikan pesawat sinar-X dalam kondisi andal dan memastikan pesawat sinar-X tersebut memenuhi persyaratan keselamatan radiasi dan memberikan informasi diagnostik yang tepat dan akurat. Uji kesesuaian pada penelitian ini dilakukan untuk menjamin keamanan pasien, pekerja radiasi, mahasiswa dan masyarakat dalam sistem pengoprasian pesawat sinar-X dengan baik dan benar. Uji yang dilakukan dalam penelitian ini adalah uji akurasi tegangan, uji akurasi waktu penyinaran, uji linearitas keluaran radiasi, uji reproduksibilitas dan uji kualitas berkas sinar-X (HVL). Alat yang digunakan adalah multimeter X-ray (RaySafe X2). Dalam pengukuran dibandingkan hasil yang terbaca pada alat dengan ketentuan yang telah ditetapkan Perka BAPETEN nomor 2 tahun 2018. Hasil yang diperoleh pada uji akurasi tegangan yaitu nilai penyimpangan terbesar adalah 1% , uji akurasi yaitu nilai penyimpangan terbesar adalah 2%, uji linearitas yang diperoleh pada fokus besar CL = 0,004 serta pada fokus kecil CL = 0,005, uji reproduksibilitas yang diperoleh pada tegangan CV = 0,0008 dan pengukuran uji nilai kualitas berkas sinar-X (HVL) adalah 2,65 mmAl pada 70 kV dan 3,05 mmAl pada 80 kV. Hasil yang dapat disimpulkan adalah pesawat sinar-X di Laboratorium Klinik, Fakultas Kedokteran Hewan, Universitas Syiah Kuala dalam kondisi yang andal sesuai Perka BAPETEN nomor 2 tahun 2018.
X- ray Machine are one of the devices that are widely available in health laboratories that are used as a tool to diagnose disease. Faculty of Veterinary, Syiah Kuala University has a Clinical Laboratory room facility with Siemens brand X-ray Machine which is used for the purposes of diagnosing diseases, especially in animals. The device has been operating for 4 (four) years and has never been tested for suitability in its operating period. Suitability test is a series of testing activities to ensure the X-ray Machine is in reliable condition and ensure that the X-ray Machine meets radiation safety requirements and provides precise and accurate diagnostic information. Suitability testing in this study were carried out to ensure the safety of patients, radiation workers, students and the public in operating X-ray Machine systems properly and correctly. The tests carried out in this study are voltage accuracy tests, irradiation time accuracy tests, radiation output linearity tests, reproducibility tests and X-ray beam (HVL) quality tests. The tool used is the X-ray multimeter (RaySafe X2). In the measurement compared to the results read on the tool with the provisions set by Perka BAPETEN number 2 of 2018. The results obtained in the voltage accuracy test are the largest deviation value is 1%, the accuracy test is the largest deviation value is 2%, the linearity test obtained at the large focus CL = 0.004 and at the small focus CL = 0.005, the reproducibility test obtained at the voltage CV = 0.0008 and the measurement of the X-ray beam quality value (HVL) test is 2.65 mmAl at 70 kV and 3.05 mmAl at 80 kV. The results that can be concluded are X-ray Machine at the Clinical Laboratory, Faculty of Veterinary Medicine, Syiah Kuala University in reliable condition according to Perka BAPETEN number 2 of 2018.
UJI KESESUAIAN PESAWAT SINAR-X MEREK MINDRAY DI INSTALASI RUANG RADIOLOGI RUMAH SAKIT UMUM MEURAXA (Egidia Tesalonika, 2024)
QUALITY COTROL (KENDALI MUTU) PESAWAT SINAR-X MERK SIEMENS HELTINERS DI INSTALASI RADIOLOGI RUMAH SAKIT PENDIDIKAN UNIVERSITAS SYIAH KUALA (Mauliana, 2024)
PEMERIKSAAN HEMATOLOGI UNTUK MENENTUKAN STATUS PRESENT KAMBING KACANG (CAPRA SP.) PADA UPT HEWAN COBA FAKULTAS KEDOKTERAN HEWAN UNIVERSITAS SYIAH KUALA (Benny Andista, S.KH, 2016)
TINGKAT PENGETAHUAN MAHASISWA KEPANITERAAN KLINIK FAKULTAS KEDOKTERAN GIGI UNIVERSITAS SYIAH KUALA MENGENAI PROSEDUR PENGAMBILAN RADIOGRAF INTRA ORAL (ZHAHWA CHURAIRAH ANSAR, 2023)
HUBUNGAN PROSES PEMBELAJARAN KOGNITIF DENGAN HASIL PENILAIAN KOGNITIF ROTASI KLINIK ILMU KEDOKTERAN FORENSIK FAKULTAS KEDOKTERAN UNIVERSITAS SYIAH KUALA TAHUN 2019 (AZARIEN AULIA, 2020)