Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
ANALISIS PERBEDAAN NILAI TIME ECHO (TE) DAN TIME REPETITION (TR) PADA KUALITAS CITRA MRI KASUS TUMOR OTAK DI RSUD DR. ZAINOEL ABIDIN
Pengarang
Elva Wirda - Personal Name;
Dosen Pembimbing
Rini Safitri - 197004251995122001 - Dosen Pembimbing I
Evi Yufita - 197509202000122001 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
1908102010026
Fakultas & Prodi
Fakultas MIPA / Fisika (S1) / PDDIKTI : 45201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas mipa., 2023
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Time Echo (TE) dan Time Repetion (TR) merupakan dua faktor parameter waktu dasar yang menentukan kualitas citra pada Magnetic Resonance Imaging (MRI). Tujuan dari penelitian ini adalah untuk mengetahui pengaruh TE dan TR terhadap SNR dan CNR pada kualitas citra kasus tumor otak. Dalam penelitian ini, data citra diambil sebanyak 9 buah dari 2 orang pasien tumor otak digunakan untuk mengevaluasi nilai SNR dan CNR pada masing-masing jaringan, yaitu pada jaringan Cerebellum Spinal Fluid (CSF), white matter, grey matter. Data-data citra tersebut memiliki sekuens yang berbeda yaitu sekuens Turbo Spin Echo (TSE) Fluid Attenuated Inversion Recovery (FLAIR) dengan masing-masing nilai TE 86 ms TR 6300 ms, dan TE 99 ms TR 8000 ms. Evaluasi nilai SNR dilakukan dengan mengukur Region of Interest (ROI) pada masing-masing jaringan dengan menggunakan program ImageJ. Hasil penelitian menunjukkan bahwa Time Echo dan Time Repetition pada jaringan CSF, WM dan GM terhadap nilai SNR yang dihasilkan pada sekuens T2 TSE (TE 86 ms dan TR 6300 ms) lebih besar dibandingkan dengan nilai SNR pada sekuens T2 FLAIR (TE 99 ms dan 8000 ms), TE dan TR berpengaruh terhadap nilai SNR dan kualitas citra. Semakin tinggi nilai SNR, maka citra yang dihasilkan juga akan semakin terang. Selanjutnya Time Echo dan Time Repetition pada penelitian ini memiliki perbedaan terhadap nilai CNR, semakin rendah nilai TE maka CNR pada citra semakin baik. CNR terbaik pada penelitian ini pada TE 99 ms dan TR 8000 ms.
Time Echo (TE) and Time Repetition (TR) are two basic time parameter factors that determine image quality in Magnetic Resonance Imaging (MRI). The purpose of this study was to determine the effect of TE and TR on SNR and CNR on image quality of brain tumor cases. In this study, 9 image data were taken from 2 brain tumor patients used to evaluate the SNR and CNR values in each tissue, namely the Cerebellum Spinal Fluid (CSF), white matter, gray matter. These image data have different sequences, namely Turbo Spin Echo (TSE) Fluid Attenuated Inversion Recovery (FLAIR) sequences with TE values of 86 ms TR 6300 ms, and TE 99 ms TR 8000 ms respectively. Evaluation of the SNR value is carried out by measuring the Region of Interest (ROI) on each network using the ImageJ program. The results showed that the Time Echo and Time Repetition values in the CSF, WM and GM networks on the SNR values produced in the T2 TSE sequence (TE 86 ms and TR 6300 ms) were greater than the SNR values in the FLAIR T2 sequence (TE 99 ms and 8000 ms), TE and TR had an effect on SNR values and image quality. The higher the SNR value, the brighter the resulting image will be. Furthermore, Time Echo and Time Repetition affect CNR, the lower the TE value, the better the CNR in the image. The best CNR in this study was at TE 99 ms TR 8000 ms in CSF tissue.
PROFIL PENDERITA TUMOR OTAK BERDASARKAN MAGNETIC RESONANCE IMAGING DI RSUD DR. ZAINOEL ABIDIN BANDA ACEH (RAIHAN MURTADHA, 2023)
DETEKSI TUMOR OTAK DENGAN MENGGUNAKAN METODE DETEKSI TEPI DAN SEGMENTASI CITRA HASIL MRI (MAGNETIC RESONANCE IMAGING) (Wiwik Ayu Ningsih, 2018)
PENGARUH TIME ECHO DAN TIME REPETITION TERHADAP SNR PADA CITRA MRI LUMBAL PENYAKIT NYERI PUNGGUNG BAWAH (ARMITHA PRADANA, 2022)
STUDI PENGARUH TIME ECHO DAN TIME REPETITION TERHADAP SIGNAL TO NOISE RATIO PADA CITRA MAGNETIC RESONANCE IMAGING WHOLE SPINE (MUHAMMAD AL FURQAN, 2023)
PENGARUH PENGGUNAAN KAPASITOR BANK TERHADAP FAKTOR DAYA PADA SISTEM KELISTRIKAN DI RSUD DR. ZAINOEL ABIDIN THE EFFECT OF USE CAPASITOR BANK TO THE POWER FACTOR IN THE ELECTRICAL SYSTEM AT RSUD DR. ZAINOEL ABIDIN (Surya Rahmad, 2019)