PENGUJIAN CBR TERENDAM MENGGUNAKAN METODE ASTM D1883-16 TERHADAP TANAH PADA JALAN TOL SIGLI – BANDA ACEH STA. 10+000 | ELECTRONIC THESES AND DISSERTATION

Electronic Theses and Dissertation

Universitas Syiah Kuala

    LAPORAN KERJA PRAKTEK

PENGUJIAN CBR TERENDAM MENGGUNAKAN METODE ASTM D1883-16 TERHADAP TANAH PADA JALAN TOL SIGLI – BANDA ACEH STA. 10+000


Pengarang

IHSAN - Personal Name;

Dosen Pembimbing

Yus Yudhyantoro - 197202032000121001 - Dosen Pembimbing I
Ruhdi Faisal - 198908142015041003 - Penguji
Banta Chairullah M - 196008151986031004 - Penguji



Nomor Pokok Mahasiswa

1904001010018

Fakultas & Prodi

Fakultas Teknik / Teknik Sipil (D3) / PDDIKTI : 22401

Subject
-
Kata Kunci
-
Penerbit

Banda Aceh : Fak. Teknik Sipil Diploma III., 2023

Bahasa

No Classification

-

Literature Searching Service

Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)

Tanah merupakan sebuah elemen utama dalam sebuah pembangunan proyek konstruksi. Tanah merupakan tempat dimana konstruksi diletakkan, oleh karena itu tanah haruslah kuat untuk dapat menahan beban yang disalurkan dari bangunan yang diletakkan di atasnya. Pengujian ini dilakukan pada Jalan tol Sigli – Banda Aceh, Kecamatan Padang Tiji Kabupaten Pidie, sampel diambil dari jalan tol STA10+000. Sampel tanah di ambil sebanyak 5 titik dengan jarak antar titik yaitu 5 meter, Tujuan dari pengujian ini adalah untuk mengetahui nilai CBR Soaked Laboratorium berdasarkan ASTM D1883-16. Untuk pengujian CBR dilakukan sebanyak 2 sampel benda uji per titik. Pengujian ini meliputi pengujian sifat-sifat fisis (berat jenis, analisis ukuran butiran dan batas-batas Atterberg), pemadatan berat dan pengujian CBR Soaked laboratorium. Hasil dari pengujian batas-batas Atterberg yang dilakukan di Laboratorium Terpadu Universitas Syiah Kuala, maka diperoleh hasil dari masing- masing benda uji yaitu: Indeks Plastisitas (PI) untuk titik satu didapatkan 14,50%, titik dua 13,92%, titik 3 10,71%, titik empat 14,41% dan titik lima didapatkan 9,60%. Berdasarkan hasil Indeks Plastisitas (PI) yang didapatkan yaitu (PI 7-17) yang memiliki plastisitas sedang, maka semua titik pada pengujian ini digolongkan ke dalam jenis tanah lempung lanau. Untuk nilai pengujian pemadatan berat menggunakan saringan No.4 untuk titik satu didapatkan hasil volume kering maksimum (γdmaks) 1.531 gr/cm3 dan kadar air optimum/Optimum Moisture Content (OMC) 19,53%, titik dua (γdmaks) 1,554 gr/cm3 dan OMC 19,46%, titik tiga (γdmaks) 1,562 gr/cm3 dan OMC 19,87%, titik empat (γdmaks) 1,519 gr/cm3 dan OMC 21,70%, titik lima (γdmaks) 1.629 gr/cm3 dan OMC 20,03%. Pengujian CBR soaked laboratorium berdasarkan ASTM D1883-16 didapatkan nilai CBR untuk titik satu 2,07%, titik dua 3,04%, titik tiga 4,44%, titik empat 2,42%, dan titik lima 5,46%. Hasil dari pengujian CBR didapatkan kriteria tanah dasar buruk untuk titik satu, dua, tiga dan empat yaitu berkisar 0-5%, sedangkan untuk titik 5 CBR nya berkisar 5-10% yang di dikategorikan tanah dasar sedang.




Kata Kunci : Pemadatan Berat, CBR Soaked Laboratorium, ASTM D1883-16







Soil is a main element in a construction project. The land is the place where construction is placed, therefore the soil must be strong to be able to withstand the load transmitted from the building placed on it. This test was carried out on the Sigli – Banda Aceh toll road, Padang Tiji District, Pidie Regency, samples were taken from the STA10+000 toll road. Soil samples were taken at 5 points with a distance between points of 5 meters. The aim of this test was to determine the CBR Soaked Laboratory value based on ASTM D1883-16. For CBR testing, 2 samples of test objects are carried out per point. This test includes physical properties testing (specific gravity, grain size analysis and Atterberg limits), heavy compaction and laboratory Soaked CBR testing. As a result of testing the Atterberg limits carried out at the Integrated Laboratory of Syiah Kuala University, the results obtained for each test object were: Plasticity Index (PI) for point one was 14.50%, point two was 13.92%, point 3 was obtained 10.71%, point four 14.41% and point five obtained 9.60%. Based on the Plasticity Index (PI) results obtained, namely (PI 7-17) which has medium plasticity, all points in this test are classified as silt clay soil types. For the heavy compaction test value using sieve No. 4 for point one, the maximum dry volume (γdmax) was 1,531 gr/cm3 and optimum moisture content (OMC) was 19.53%, point two (γdmax) was 1,554 gr/cm3 and OMC 19.46%, point three (γdmax) 1.562 gr/cm3 and OMC 19.87%, point four (γdmax) 1.519 gr/cm3 and OMC 21.70%, point five (γdmax) 1,629 gr/cm3 and OMC 20.03%. Laboratory soaked CBR testing based on ASTM D1883-16 obtained a CBR value for point one of 2.07%, point two of 3.04%, point three of 4.44%, point four of 2.42%, and point five of 5.46%. The results of the CBR test showed that the criteria for poor subgrade for points one, two, three and four were around 0-5%, while for point 5 the CBR was around 5-10% which was categorized as medium subgrade.