Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
EVALUASI KINERJA STRUKTUR BANGUNAN GEDUNG TERHADAP ANALISIS PUSHOVER SERTA ALTERNATIF PERBAIKAN
Pengarang
RISKI AULIA - Personal Name;
Dosen Pembimbing
Surya Bermansyah - 197210022000031002 - Dosen Pembimbing I
Yulia Hayati - 197107091997022002 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
1804101010066
Fakultas & Prodi
Fakultas Teknik / Teknik Sipil (S1) / PDDIKTI : 22201
Subject
Penerbit
Banda Aceh : Fakultas Teknik Sipil., 2023
Bahasa
Indonesia
No Classification
690
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Perencanaan gedung tahan gempa di Indonesia sangat penting karena sebagian besar wilayahnya merupakan wilayah gempa yang mempunyai intensitas moderat hingga tinggi. Struktur bangunan harus direncanakan sesuai dengan kaidah-kaidah perencanaan yang berlaku, sehingga pada saat terjadi gempa, struktur bangunan tersebut mampu bertahan dan tidak mengalami kegagalan struktur yang signifikan. Objek penelitian ini adalah sebuah bangunan simulasi dari penelitian terdahulu yang diasumsikan dibangun di Kota Banda Aceh. Bangunan rumah sakit ini memiliki 7 lantai termasuk lantai dasar dengan tinggi total dari lantai dasar 31,56 m dengan ukuran 23 m untuk arah y dan 34 m untuk arah x. Penelitian ini bertujuan untuk mengevaluasi perilaku struktur bangunan yaitu perpindahan (displacement), gaya geser (base shear), simpangan antar lantai (story drift), torsi, guling serta analisis pushover. Hasil penelitian ini menunjukkan nilai performance point gedung rumah sakit pada arah x diperoleh nilai base shear maksimum sebesar 12334,276 kN dengan displacement sebesar 186,547 mm, sedangkan untuk arah y diperoleh nilai base shear maksimum sebesar 13434,074 kN dengan displacement sebesar 240,864 mm. Berdasarkan nilai performance point dari analisis pushover arah x dan arah y maka level kinerja struktur bangunan rumah sakit berada pada level LS (life safety). Perbaikan struktur dilakukan untuk meningkatkan kekuatan elemen struktur agar struktrur berada pada level yang aman sesuai dengan standar yang berlaku.
The planning of earthquake-resistant buildings in Indonesia is very important because most of the region is an earthquake area with moderate to high intensity. Building structures must be planned according to applicable planning principles so that, in the event of an earthquake, the building structure is able to survive and not experience significant structural failure. The object of this research is a simulation building from previous research that is assumed to be built in the city of Banda Aceh. This hospital building has 7 floors, including the ground floor, with a total height of the ground floor of 31,56 m with a size of 23 m for the y direction and 34 m for the x direction. This study aims to evaluate the behavior of building structures, namely displacement, base shear, story drift, torsion, overturning, pushover analysis. The results of this study indicate the performance point value of the hospital building in the x direction obtained a maximum base shear value of 12334.276 kN with a displacement of 186.547 mm, while for the y direction a maximum base shear value of 13434.074 kN was obtained with a displacement of 240.864 mm. Based on the performance point values from the pushover analysis in the x and y directions, the performance level of the hospital building structure is at the LS (life safety) level. Structural improvements are carried out to increase the strength of structural elements so that the structure is at a safe level in accordance with applicable standards.
EVALUASI KINERJA STRUKTUR BANGUNAN GEDUNG SERBA GUNA KABUPATEN PIDIE JAYA AKIBAT GEMPA DENGAN MENGGUNAKAN ANALISIS PUSHOVER (Shofiyatul Khairiyah Nasty, 2019)
EVALUASI KINERJA STRUKTUR BANGUNAN KOMPOSIT BAJA-BETON DENGAN ANALISIS PUSHOVER BERDASARKAN DATA PETA GEMPA TAHUN 2012 (STUDI KASUS: GEDUNG BPJN I BANDA ACEH) (SITI ZUHRA SHALIHA, 2020)
EVALUASI KINERJA STRUKTUR BANGUNAN KOMPOSIT BAJA-BETON DENGAN ANALISIS PUSHOVER BERDASARKAN DATA PETA GEMPA TAHUN 2017 (Herry Ramadhana, 2020)
EVALUASI KINERJA STRUKTUR GEDUNG BETON BERTULANG DENGAN BASE ISOLATOR MENGGUNAKAN ANALISIS BEBAN DORONG (PUSHOVER) (FITRY HASDANITA, 2017)
KINERJA STRUKTUR RUANG AULA GEDUNG SERBAGUNA KABUPATEN PIDIE JAYA TERHADAP GEMPA DENGAN ANALISIS PUSHOVER (GILBY RIVANO BILQAINY, 2020)