STUDI PERPINDAHAN PANAS PADA MENARA PENDINGIN TIPE PELAT DATAR BERLUBANG DENGAN VARIASI BENTUK LUBANG
Pengarang
Yulanda Dwi Mustika - Personal Name;
Dosen Pembimbing
Razali - 196505051991021001 - Dosen Pembimbing I
Ahmad Syuhada - 196108201987031002 - Dosen Pembimbing I
Nomor Pokok Mahasiswa
1904102010028
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Penerbit
Banda Aceh : Fakultas Teknik Mesin., 2023
Bahasa
Indonesia
No Classification
621.402 2
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Menara pendingin (cooling tower) merupakan salah satu sistem pendingin yang paling banyak digunakan pada dunia industri. Cooling tower merupakan rangkaian alat penukar panas yang memiliki fluida kerja berupa air dan udara yang berfungsi sebagai media pendingin dengan cara berkontak langsung dengan udara. Tujuan dari penelitian ini adalah untuk mendapatkan sistem cooling tower yang optimal dengan mendapatkan nilai koefisien perpindahan panas konveksi konveksi. Guna meningkatkan kinerja menara pendingin, banyak peneliti yang telah melakukan penelitian mengenai hal ini akan tetapi masih perlu ditingkatkan agar mendapat hasil yang lebih optimal. Dengan fenomena tersebut, penelitian ini dilakukan dengan mempelajari proses perpindahan panas yang terjadi pada pelat berlubang terhadap koefisien perpindahan panas konveksi konveksi pada menara pendingin tipe pelat datar dengan tinggi keseluruhan menara sebesar 2,4 m, dan jumlah media pendistribusi fluida sebesar 5 pelat yang disusun secara bertingkat. Panjang pada setiap pelat yaitu 0,7 m dengan lebar 0,5 m. Adapula variasi yang dilakukan pada menara pendingin bertingkat yaitu terdapat pada bentuk lubang yang digunakan. Bentuk lubang yang digunakan ialah bentuk lingkaran, segitiga dan persegi empat dengan menggunakan model lubang outlet zig – zag. Luas pelat yang berlubang 0,0157 m2 pada setiap pelat nya dengan rasio kemiringan setiap susunan pelat yaitu 15º. Hasil penelitian menunjukkan bahwa nilai koefisien perpindahan panas konveksi konveksi tertinggi terjadi pada menara pendingin bertingkat dari temperatur inlet 60ºC, 70ºC, 80ºC yaitu pada penggunaan pelat dengan bentuk persegi empat, lalu diikuti dengan bentuk segitiga dan bentuk lingkaran memiliki nilai koefisien perpindahan panas konveksi konveksi terendah. Dengan penurunan temperatur yang terjadi pada tipe lubang persegi empat sebesar 35,1ºC, sehingga didapatkan nilai laju perpindahan panas sebesar 7.80,333940 kW dan nilai koefisien perpindahan panas konveksi sebesar 59,21518689 kW/m2K
Cooling towers are one of the most widely used cooling systems in the industrial world. A cooling tower consists of a heat exchanger system with the working fluids being water and air, which serve as the cooling media by making direct contact with the air. The aim of this research is to obtain an optimal cooling tower system by achieving a convective heat transfer coefficient value. To enhance the performance of cooling towers, many researchers have conducted studies on this subject. However, further improvements are necessary to achieve more optimal results. Given this phenomenon, this study focuses on understanding the heat transfer process that occurs on perforated plates concerning the convective heat transfer coefficient in a multi-stage flat plate cooling tower. The overall height of the tower is 2.4 m, with 5 fluid distribution plates arranged in tiers. Each plate has a length of 0.7 m and a width of 0.5 m. The variation in this multi-stage cooling tower lies in the shape of the holes used. The hole shapes include circles, triangles, and squares, utilizing a zig-zag outlet hole pattern. The perforated plate area is 0.0157 m² for each plate, and the inclination angle of each plate arrangement is 15º. The research results reveal that the highest convective heat transfer coefficient value occurs in the multi-stage cooling tower with inlet temperatures of 60ºC, 70ºC, and 80ºC when using square-shaped plates. This is followed by triangular plates, and circular plates have the lowest convective heat transfer coefficient value. The temperature decrease for the square hole type is 35.1ºC, resulting in a heat transfer rate of 780.333940 kW and a convective heat transfer coefficient value of 59.21518689 kW/m²K.
PENGARUH JUMLAH LUBANG PELAT SEKAT MENARA PENDINGIN (COOLING TOWER) TERHADAP KEOPTIMALAN PERPINDAHAN PANAS (Heli Suansyah, 2023)
KAJIAN EKSPERIMENTAL PENGARUH JUMLAH LUBANG PLAT TERHADAP PERPINDAHAN PANAS KONVEKSI PADA MENARA PENDINGIN TIPE PLAT DATAR (Asra Yufandi, 2021)
ANALISA PENGARUH JUMLAH LUBANG TERHADAP PERPINDAHAN PANAS PADA COOLING TOWER PLAT DATAR BERTINGKAT MENGGUNAKAN SIMULASI CFD (Yulanda Dwi Mustika, 2024)
KAJIAN KARAKTERISTIK PERPINDAHAN PANAS PADA MENARARNPENDINGIN TIPE PLAT DATAR BERTINGKAT AKIBAT PENGARUHRNLETAK LUBANG (AFDHALUL RAJAI, 2022)
PENGARUH JUMLAH LUBANG PADA MENARA PENDINGIN TIPE PLAT DATAR BERTINGKAT BERLUBANG TERHADAP KARAKTERISTIK PERPINDAHAN PANAS (Afdhalul rajai El faridy, 2023)