PENGARUH JUMLAH LUBANG PADA MENARA PENDINGIN TIPE PLAT DATAR BERTINGKAT BERLUBANG TERHADAP KARAKTERISTIK PERPINDAHAN PANAS
Pengarang
Afdhalul rajai El faridy - Personal Name;
Dosen Pembimbing
Ahmad Syuhada - 196108201987031002 - Dosen Pembimbing I
Razali - 196505051991021001 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
2204202010003
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S2) / PDDIKTI : 21101
Subject
Penerbit
Banda Aceh : Program Studi Magister Teknik Mesin Universitas Syiah Kuala., 2023
Bahasa
Indonesia
No Classification
621.402 2
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Menara pendingin yang di teliti adalah suatu alat penukar panas melalui media pendingin berupa fluida kerjanya air, beserta udara yang dimanfaatkan untuk mendinginkan panas melalui media air dengan kontak langsung dengan udara secara turbolensi yang mengakibatkan sebagian kecil air menguap. Untuk meningkatkan kinerja menara pendingin telah banyak dilakukan pengujian. Sehinngga penelitian ini mengkaji pengaruh yang terjadi pada jumlah lubang terhadap laju perpindahan pada menara pendingin tipe plat datar dengan tinggi keseluruhan menara pendingin 2,4 m, banyak jumlah media pendistribusi aliran air menara pendingin yaitu 5 plat secara bertingkat, panjang tiap plat yaitu 0,7 m dengan lebar 0,5 meter. Variasi plat diberikan pada menara pendingin yaitu plat tanpa lubang, plat 25 lubang plat, 35 lubang, 45 lubang, 55 lubang, dan 65 lubang model lubang zig-zag pada menara pendingin. Diameter tiap lubang plat yang di berikan memiliki ukuran 0,02 m dengan rasio kemiringan setiap plat yaitu 150. Hasil penelitian menunjukkan laju perpindahan panas tertinggi terjadi pada menara pendingin temperatur air masuk 750C variasi plat yang digunakan dengan jumlah lubang sebanyak 45. dan laju perpindahan panas paling rendah terjadi pada temperatur air masuk 550C variasi plat 25 lubang.
The cooling tower studied is a heat exchanger through a cooling medium in the form of a working fluid, water, along with air, which is used to cool heat through water media with direct contact with air by means of turbolence which causes a small part of the water to evaporate. To improve the performance of cooling towers, many tests have been carried out. So that this study examines the effect that occurs on the number of holes on the rate of transfer in a flat plate type cooling tower with an overall height of 2.4 m cooling tower, the number of media distributing the cooling tower water flow is 5 plates in stages, the length of each plate is 0.7 m with a width of 0.5 meters. Plate variations are given to cooling towers, namely plates without holes, plates with 25 holes, 35 holes, 45 holes, 55 holes, and 65 holes with zig-zag holes in the cooling tower. The diameter of each plate hole given is 0.02 m in size with a slope ratio of 150 for each plate. The results showed that the highest heat transfer rate occurred in the cooling tower with an inlet water temperature of 750C, the variation of the plate used with 45 holes and the heat transfer rate. the lowest occurred at the inlet water temperature of 550C plate variation 25 holes.
KAJIAN KARAKTERISTIK PERPINDAHAN PANAS PADA MENARARNPENDINGIN TIPE PLAT DATAR BERTINGKAT AKIBAT PENGARUHRNLETAK LUBANG (AFDHALUL RAJAI, 2022)
KAJIAN EKSPERIMENTAL PENGARUH JUMLAH LUBANG PLAT TERHADAP PERPINDAHAN PANAS KONVEKSI PADA MENARA PENDINGIN TIPE PLAT DATAR (Asra Yufandi, 2021)
KAJIAN PERPINDAHAN PANAS PADA MENARA PENDINGIN (COOLING TOWER) TIPE PLAT DATAR BERLUBANG SEGITIGA (Fikri Aulia, 2023)
ANALISA PENGARUH JUMLAH LUBANG PADA MENARA PENDINGIN TIPE PLAT DATAR BERTINGKAT BANYAK TERHADAP KARAKTERISTIK PERPINDAHAN PANAS (ALIFIA KANEYSHA PERANGIN-ANGIN, 2024)
ANALISA PENGARUH KECEPATAN UDARA PADA MENARA PENDINGIN TIPE PLAT DATAR BERLUBANG BERTINGKAT BANYAK TERHADAP KARAKTERISTIK PERPINDAHAN PANAS (, 2024)