Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
ANALISIS INTENSITAS MEDAN DAN LEVEL RADIASI ELEKTROMAGNETIK BASE TRANSCEIVER STATION (BTS) STANDARDISASI ICNIRP
Pengarang
Putra Khabulin - Personal Name;
Dosen Pembimbing
Syahrial - 196401121992031003 - Dosen Pembimbing I
Al Bahri - 199109102019031014 - Dosen Pembimbing II
Muhammad Irhamsyah - 197207182001121001 - Penguji
Ernita Dewi Meutia - 196809041992032001 - Penguji
Zulfikar - 197507202006041003 - Penguji
Nomor Pokok Mahasiswa
1904105010002
Fakultas & Prodi
Fakultas Teknik / Teknik Elektro (S1) / PDDIKTI : 20201
Subject
Penerbit
Banda Aceh : Fakultas Teknik Elektro., 2023
Bahasa
Indonesia
No Classification
621.382
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Pesatnya perkembangan industri telekomunikasi tidak luput dari adanya menara BTS sebagai penunjang terbesar teknologi informasi. Problematika yang dirasakan adalah tersebarnya isu kesehatan yang diyakini dapat membahayakan kesehatan masyarakat disebabkan oleh paparan radiasi dari menara BTS. Hal ini perlu disosialisasikan dan dibuktikan berdasarkan data untuk menghindari kesalahpahaman tentang masalah kesehatan yang belum terbukti kebenarannya. Tingkat radiasi yang dipancarkan oleh antena menara BTS dilakukan perbandingan dengan batas aman dalam standar toleransi yang di tetapkan oleh ICNIRP yaitu 10 W/m2 untuk perangkat elektronik yang bekerja pada frekuensi 2-300 GHz. Metode yang digunakan dalam penelitian ini adalah pengumpulan data secara langsung pada menara BTS Telkomsel dan XL Axiata dengan mengukur nilai medan listrik E dan medan magnet B. Pengambilan data dilakukan di 3 waktu yang berbeda yaitu pagi, siang, dan sore hari untuk dilihat paparan radiasi pada waktu tersebut. Pengukuran dilakukan melalui beberapa garis dengan jarak yang bervariasi mulai dari 0 sampai 30 meter dari menara BTS. Medan radiasi yang diperoleh dilakukan perhitungan untuk mencari nilai level radiasi. Hasil penelitian menunjukkan level radiasi terbesar yang dipancarkan oleh menara BTS Telkomsel dan XL Axiata dari pagi sampai sore hari bernilai 1.45 W/m2 untuk dan 1,36 W/m2. Nilai tersebut masih jauh tergolong aman dalam standar toleransi yang ditetapkan oleh ICNIRP sehingga paparan radiasi dari kedua menara BTS tersebut tidaklah berbahaya bagi kesehatan masyarakat.
Kata kunci: Radiasi Elektromagnetik, Medan Radiasi, Medan Listrik, Medan Magnet, ICNIRP, BTS.
The rapid development of the telecommunications industry is inseparable from the presence of BTS towers as the biggest supporter of information technology. The perceived problem is the spread of health issues that are believed to endanger public health caused by radiation exposure from BTS towers. This needs to be socialized and proven based on data to avoid misunderstandings about health problems that have not been proven true. The radiation level emitted by the BTS tower antenna is compared with the safe limit in the standard tolerance set by the ICNIRP, which is 10 W/m2 for electronic devices operating at a frequency of 2-300 GHz. The method used in this research is direct data collection on Telkomsel and XL Axiata BTS towers by measuring the value of the electric field E and magnetic field B. Data collection was carried out at 3 different times, namely morning, afternoon and evening to see radiation exposure on that time. Measurements were made through several lines with varying distances from 0 to 30 meters from the BTS tower. The radiation field obtained is calculated to find the radiation level value. The results showed that the highest radiation level emitted by Telkomsel and XL Axiata BTS towers from morning to evening was 1.45 W/m2 for and 1.36 W/m2. This value is still far from being safe within the tolerance standard set by the ICNIRP so that radiation exposure from the two BTS towers is not dangerous to public health. Keywords: Electromagnetic Radiation, Radiation Field, Electric Field, Magnetic Field, ICNIRP, BTS.
ANALISIS INTENSITAS MEDAN DAN LEVEL RADIASI ELEKTROMAGNETIK BASE TRANSCEIVER STATION (BTS) STANDARDISASI ICNIRP (Putra Khabulin, 2023)
STUDI INTENSITAS RADIASI ELEKTROMAGNETIK DISEKITAR SALURAN UDARA TEGANGAN TINGGI 150 KV (Rendi Ramadhan Putra, 2024)
PERANCANGAN ALAT PENGUKUR RADIASI MEDAN ELEKTROMAGNETIK STUDI KASUS HANDPHONE NOKIA 1102 (MUHIBBAN, 2016)
SURVEY RADIASI MEDAN ELEKTROMAGNETIK YANG DITIMBULKAN OLEH KOMPUTER (Elli Yani, 2022)
ANALISIS SEBARAN ELECTROMAGNETIC FIELDS DI SEKITAR PERALATAN MEDIS RUMAH SAKIT UMUM DAERAH TENGKU ABDULLAH SYAFI'I BEUREUNUEN (Syifa Tazkia, 2024)