PERANCANGAN SISTEM HEATING VENTILATION AND AIR CONDITIONING (HVAC) PADA RUANG ISOLASI PASIEN PENYAKIT MENULAR
Pengarang
MUHAMMAD SYAHRIL - Personal Name;
Dosen Pembimbing
Ahmad Syuhada - 196108201987031002 - Dosen Pembimbing I
Hamdani - 196511071991021001 - Dosen Pembimbing II
Nomor Pokok Mahasiswa
1804102010068
Fakultas & Prodi
Fakultas Teknik / Teknik Mesin (S1) / PDDIKTI : 21201
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Teknik - Teknik Mesin., 2022
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
Sistem pemanas, sirkulasi udara dan pendingin di dalam satu sistem. Sistem HVAC memberikan kenyamanan bagi penghuni yang berada di dalam ruangan isolasi waktu yang lama untuk melakukan aktivitas. Pemilihan suatu sistem pengkondisian udara harus tepat kebutuhan ruangan isolasi sehingga memberikan hasil yang maksimal. Pada perancangan suatu sistem pengkondisian udara harus terlebih dahulu di hitung beban pendingin yang terdiri dari perhitungan beban pendingin yang berasal dari internal dan external, kemudian analisa psychometric, dan perhitungan COP secara teoritis setelah itu dapat dipilih dan dipasang kapasitas mesin pendingin yang sesuai ruangan isolasi yang akan dikondisikan. Berdasarkan hasil perhitungan kapasitas pendingin untuk ruangan isolasi sebesar 349.809, 575 Btu/h atau 29,15 Ton Refrigerasi dan kapasitas pemanasan untuk reheat sebesar 368.305 Btu/h, nilai Cop sebesar 5,57 dan kerja kompresor didapatkan sebesar 18830 watt.
Air circulation and cooling system in one system. The HVAC system provides comfort for occupants inside isolation room for a long time to carry out activities. Selection of a The air conditioning system must match the needs of the room so that provide maximum results. In designing a system air conditioning must first calculate the cooling load consists of calculating the cooling load originating from internal and external external, then psychometric analysis, and theoretical COP calculations after that it can be selected and installed the appropriate cooling engine capacity isolation room to be conditioned. Result Based on calculation cooling capacity for isolation rooms is 349,809, 575 Btu/h or 29.15 Tons Refrigeration and heating capacity for reheat is 368,305 Btu/h, the Cop value is 5.57 and the compressor work is 18830 watt.
PENGEMBANGAN HEAT PIPE HEAT EXCHANGER (HPHE) UNTUK MENINGKATKAN KONSERVASI ENERGI PADA SISTEM TATA UDARA (Fazri, 2024)
PERANCANGAN SISTEM DAN INSTALASI TATA UDARA RUANG ISOLASI BERTEKANAN NEGATIF (Shahibul Mighvar, 2023)
PERANCANGAN SISTEM HEATING VENTILATION AND AIR CONDITIONING (HVAC) PADA RUANG ISOLASI PASIEN PENYAKIT MENULAR (MUHAMMAD SYAHRIL, 2022)
EVALUASI UNJUK KERJA AIR HEATING UNIT PADA GUDANG PENYIMPAN UREA CURAH PT. PUPUK ISKANDAR MUDA (Heri Setiawan, 2024)
GAMBARAN PENYAKIT KLIEN YANG BEROBAT DI PUSKESMAS KOTAMADYA BANDA ACEH (YURI RORITA, 2017)