Electronic Theses and Dissertation
Universitas Syiah Kuala
SKRIPSI
AKURASI DIAGNOSA ESTRUS BERDASARKAN ELECTRICAL RESISTANCE OF VAGINAL MUCUS (ERVM) PADA SAPI ACEH (ACCURATION OF ESTROUS DIAGNOSIS BASED ON ELECTRICAL RESISTANCE OF VAGINAL MUCUS (ERVM) IN ACEH CATTLE)
Pengarang
MUHAMMAD RIZKI RAMADHANI - Personal Name;
Dosen Pembimbing
Cut Nila Thasmi - 196206111986032002 - Dosen Pembimbing I
Herrialfian - 197705122006041003 - Dosen Pembimbing II
Gholib - 198203212014041001 - Penguji
Tongku Nizwan Siregar - 196909011994031003 - Penguji
Amiruddin - 196508171993031005 - Penguji
Nomor Pokok Mahasiswa
1802101010184
Fakultas & Prodi
Fakultas Kedokteran Hewan / Pendidikan Kedokteran Hewan (S1) / PDDIKTI : 54261
Subject
Kata Kunci
Penerbit
Banda Aceh : Fakultas Kedokteran Hewan., 2022
Bahasa
No Classification
-
Literature Searching Service
Hard copy atau foto copy dari buku ini dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan hubungi via telegram (Chat Services LSS)
ABSTRAK
Peternak sering mengalami kendala pada saat mendeteksi estrus sehingga sapi mengalami kegagalan bunting dan kawin berulang mengakibatkan kerugian finansial bagi peternak karena berkurangnya produksi ternak. Peningkatan produktivitas reproduksi bisa dilakukan ketika siklus estrus dengan deteksi estrus yang akurat untuk mengetahui waktu inseminasi yang tepat. Penelitian ini bertujuan mengetahui akurasi dari metode deteksi Electrical Resistance of Vaginal Mucus (ERVM) dalam mendeteksi estrus pada sapi aceh. Dalam penelitian digunakan sapi aceh 12 ekor, berumur 3-5 tahun, bobot badan 150-250 kg dan sehat secara klinis. Sebelum melakukan sinkronisasi birahi dilakukan palpasi rektal untuk mengetahui status reproduksi apakah dalam fase folikuler atau fase luteal, seluruh sapi disinkronisasi dengan menggunakan prostaglandin F2 alpha (PGF2α) sebanyak 5 ml secara intra muskulus dengan pola penyuntikan tunggal. Deteksi estrus menggunakan metode pengukuran ERVM dilakukan menggunakan detektor estrus Draminski sebanyak tiga kali dan diambil rata-ratanya. Hasil pemeriksaan estrus dengan ERVM dikonfirmasi dengan adanya sekresi mukus serviks (gold standard) setelah snkronisasi. Deteksi estrus dilakukan dengan menggunakan metode pengukuran ERVM, data yang diperoleh dari hasil pengukuran ERVM dihitung nilai sensitivitas, spesifitas dan akurasinya. Hasil penelitian ini menunjukkan bahwa rata-rata nilai ERVM pada sapi aceh saat estrus sebesar 197,22±5,34 Ω, pada sapi aceh yang tidak estrus rata-rata nilai ERVM 313,33±29,29 Ω, sensitivitas (100%), spesifisitas (100%) dan akurasinya (100%). Berdasarkan hasil penelitian dapat disimpulkan bahwa deteksi estrus menggunakan metode pengukuran ERVM memiliki tingkat akurasi yang tinggi, sehingga penggunaan metode deteksi estrus tersebut dapat menjadi rekomendasi dalam mempercepat diagnosa/deteksi estrus bagi peternak pada sapi aceh untuk melakukan inseminasi buatan.
Kata kunci: ERVM, Estrus, Sapi aceh, Sinkronisasi
ABSTRACT Breeders often experience problems when detecting estrus so that cows fail to get pregnant and mate repeatedly resulting in losses for farmers due to reduced livestock production. productivity can be done during the estrus cycle with accurate estrus detection to determine the increase in the right insemination time. This study aims to determine the accuracy of the detection of Electrical Resistance of Vaginal Mucus (ERVM) in detecting estrus in Aceh cattle. In the study, there were 12 aceh cattle, 3-5 years old, body weight 150-250 kg and clinically healthy. Before synchronizing lust, rectal palpation was performed to determine reproductive status whether in the follicular phase or luteal phase, all cows were synchronized using 5 ml of prostaglandin F2 alpha (PGF2α) intramuscularly with a single injection pattern. Detection of estrus using the ERVM measurement method was carried out using the Draminski estrus detector three times and the average was taken. The results of estrus examination with ERVM were confirmed by the presence of cervical mucus secretion (gold standard) after synchronization. Detection of estrus is carried out using the ERVM measurement method, the data obtained from the ERVM measurement results are calculated for the sensitivity, specificity and accuracy values. The results of this study indicate that the average value of ERVM in Aceh cattle during estrus is 197.22±5.34, in Aceh cattle that are not estrus the average ERVM value is 313.33±29.29, sensitivity (100%), specificity (100%) and accuracy (100%). Based on the results of the study, it can be found that estrus detection using the ERVM measurement method has a high level of accuracy, so that the use of this method can be a recommendation in estrus diagnosis/detection recommendations for farmers in Aceh cattle to perform artificial insemination Keywords: Aceh cattle, ERVM, Estrus, Synchronization
AKURASI DIAGNOSA ESTRUS BERDASARKAN ELECTRICAL RESISTANCE OF VAGINAL MUCUS (ERVM) PADA SAPI ACEH (ACCURATION OF ESTROUS DIAGNOSIS BASED ON ELECTRICAL RESISTANCE OF VAGINAL MUCUS (ERVM) IN ACEH CATTLE) (MUHAMMAD RIZKI RAMADHANI, 2022)
HUBUNGAN ANTARA BEBERAPA PROFIL BIOKIMIA DARAH DENGAN VISKOSITAS MUKUS SERVIKS SAPI ACEH YANG MENGALAMI SINKRONISASI BIRAHI (FATHUR RAZAK, 2018)
PENGARUH PH MUKUS SERVIKS SAPI ACEH TERHADAP DAYA PENETRASI SPERMA (ROMY AMANSYAH, 2018)
PROFIL HORMON ESTRADIOL SAPI ACEH SELAMA SATU SIKLUS BERAHI (juliana Rossa, 2014)
PERBANDINGAN SPESIES CANDIDA SP. PADA RONGGA MULUT DAN VAGINA SAPI ACEH (CHICI JUSTITIA LARIKA, 2020)