Reyka Dila Gustriana, ANALISIS HUBUNGAN PARAMETER EKSPOSI DAN TEBAL KOMPRESI TERHADAP NILAI AVERAGE GLANDULAR DOSE (AGD) PADA PASIEN MAMOGRAFI. Banda Aceh Fakultas MIPA Fisika,2026

Pemeriksaan mamografi merupakan metode skrining yang efektif dalam deteksi dini kanker payudara, namun penggunaan radiasi sinar-x menimbulkan potensi risiko terhadap jaringan yang bersifat radiosensitif, khususnya jaringan kelenjar payudara. oleh karena itu, diperlukan evaluasi dosis radiasi menggunakan parameter average glandular dose (agd) guna memastikan keselamatan pasien sesuai prinsip proteksi radiasi. penelitian ini bertujuan untuk menganalisis hubungan antara parameter eksposi berupa tegangan tabung, arus-waktu tabung, dan tebal kompresi payudara terhadap nilai agd, serta mengevaluasi kesesuaiannya dengan standar yang ditetapkan oleh iaea dan bapeten, serta meninjau implikasinya terhadap risiko radiasi pada jaringan payudara. penelitian ini merupakan penelitian kuantitatif observasional dengan pendekatan retrospektif. sampel penelitian dipilih menggunakan teknik purposive sampling dan terdiri atas 59 data pasien yang menjalani pemeriksaan mamografi menggunakan pesawat siemens mammomat inspiration. variabel yang dianalisis meliputi tegangan tabung, arus-waktu tabung, tebal kompresi payudara, dan nilai agd pada proyeksi craniocaudal (cc) dan mediolateral oblique (mlo). analisis data dilakukan menggunakan statistik deskriptif, uji normalitas, dan uji korelasi spearman. diperoleh rata-rata nilai agd pada proyeksi cc sebesar 0,90 ± 0,41 mgy dan pada proyeksi mlo sebesar 1,29 ± 0,62 mgy. terdapat hubungan positif dan signifikan antara tegangan tabung, arus-waktu tabung, serta tebal kompresi payudara terhadap nilai agd (p < 0,05). arus-waktu tabung menunjukkan hubungan paling kuat dengan nilai agd, dengan koefisien korelasi sebesar r = 0,933 pada proyeksi cc dan r = 0,989 pada proyeksi mlo. tegangan tabung memiliki korelasi kuat terhadap nilai agd (r = 0,718 pada cc dan r = 0,653 pada mlo), sedangkan tebal kompresi menunjukkan korelasi kuat (r = 0,735 pada cc dan r = 0,690 pada mlo). seluruh nilai agd yang diperoleh masih berada di bawah batas referensi yang direkomendasikan oleh iaea (2 mgy) dan bapeten (1,8 mgy) per proyeksi. arus-waktu tabung merupakan faktor yang paling dominan terhadap peningkatan nilai agd. meskipun terjadi peningkatan nilai agd seiring bertambahnya parameter eksposi dan tebal kompresi, seluruh nilai yang diperoleh masih berada dalam batas aman sesuai standar yang berlaku sehingga mendukung penerapan prinsip alara dalam pemeriksaan mamografi.



Abstract

Mammography examination is an effective screening method for the early detection of breast cancer; however, the use of X-ray radiation poses potential risks to radiosensitive tissues, particularly the breast glandular tissue. Therefore, radiation dose evaluation using the Average Glandular Dose (AGD) parameter is required to ensure patient safety in accordance with radiation protection principles. This study aimed to analyze the relationship between exposure parameters, including tube voltage, tube current–time product, and breast compression thickness, with AGD values, as well as to evaluate their compliance with standards established by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Regulatory Agency of Indonesia (BAPETEN), and to assess their implications for radiation risk in breast tissue. This research was a quantitative observational study with a retrospective approach. The sample was selected using a purposive sampling technique and consisted of 59 patient data records who underwent mammography examinations using a Siemens Mammomat Inspiration system. The variables analyzed included tube voltage, tube current–time product, breast compression thickness, and AGD values in the craniocaudal (CC) and mediolateral oblique (MLO) projections. Data analysis was performed using descriptive statistics, normality tests, and Spearman correlation tests. The mean AGD values were 0.90 ± 0.41 mGy for the CC projection and 1.29 ± 0.62 mGy for the MLO projection. The results showed a positive and statistically significant relationship between tube voltage, tube current–time product, and breast compression thickness with AGD values (p < 0.05). The tube current–time product demonstrated the strongest correlation with AGD, with correlation coefficients of r = 0.933 for the CC projection and r = 0.989 for the MLO projection. Tube voltage showed a strong correlation with AGD (r = 0.718 for CC and r = 0.653 for MLO), while breast compression thickness also demonstrated a strong correlation (r = 0.735 for CC and r = 0.690 for MLO). All obtained AGD values were below the reference levels recommended by the IAEA (2 mGy) and BAPETEN (1.8 mGy) per projection. The tube current–time product was identified as the most dominant factor influencing the increase in AGD values. Although AGD increased with higher exposure parameters and compression thickness, all values remained within safe limits according to applicable standards, thereby supporting the implementation of the ALARA principle in mammography examinations.



    SERVICES DESK