Ghina Amira, KINERJA SISTEM VENTILASI ALAMI TERHADAP KENYAMANAN TERMAL PADA MASJID VERNAKULAR (STUDI KASUS : MASJID TUHA INDRAPURI). Banda Aceh Fakultas Teknik,2025

Masjid merupakan tempat ibadah bagi umat muslim. sulitnya mencapai kenyamanan termal pada bangunan masjid disebabkan oleh suhu udara tinggi dan kecepatan angin yang rendah. masjid tuha indrapuri merupakan salah satu masjid vernakular yang dibangun pada tahun 1607 – 1636 m. meskipun usianya sudah ratusan tahun, masjid ini masih aktif digunakan hingga saat ini, dan sudah ditetapkan sebagai situs cagar budaya berdasarkan surat keputusan penetapan menteri no.014/m/1999. untuk menjaga eksistensinya, penelitian tentang kenyamanan termal melalui sistem ventilasi alami penting untuk dilakukan, agar masjid tuha indrapuri tetap menjadi tujuan untuk beribadah baik bagi masyarakat setempat maupun wisatawan. masjid ini berlokasi di desa pasar indrapuri, kecamatan indrapuri, kabupaten aceh besar, provinsi aceh. penelitian ini bertujuan untuk mengevaluasi kondisi termal dan menganalisis kinerja sistem ventilasi alami. penelitian ini menggunakan pendekatan kuantitatif dengan menggabungkan observasi lapangan, pengukuran langsung iklim mikro bangunan, survei respon penggun selama 3 hari yaitu dari pukul 10:00 hingga pukul 16:00, dan simulasi menggunakan aplikasi ansys fluent untuk melihat kinerja ventilasi. data dari pengamatan, pengukuran, dan kuesioner diintegrasikan untuk memberikan evaluasi yang komprehensif terhadap kinerja termal bangunan dan sistem ventilasi yang unik. hasilnya dibandingkan dengan standar nasional indonesia (sni 03-6572-2001) untuk menilai efektivitas stack effect dalam menjaga kenyamanan termal. hasil penelitian menunjukkan bahwa masjid tuha indrapuri memiliki nilai rata-rata suhu efektif 27.4°c, yang berarti bangunan secara umum memiliki sensasi termal hangat nyaman ambang batas. pengguna merasakan bahwa kondisinya cukup memadai untuk kegiatan ibadah. kinerja ventilasi masjid tuha indrapuri sudah sesuai dengan prinsip penerapan stack effect dimana selisih suhu antara t1-t6 sebesar 1.6°c pada saat kondisi cuaca mendung, dan 3.3°c pada saat kondisi cuaca cerah. berdasarkan simulasi, menunjukkan bahwa angin pada atap kedua mempunyai peran penting untuk mengeluarkan udara dari dalam dibandingkan dengan kondisi ventilasi eksisting yang tertutup. kata kunci : ventilasi alami, kenyamanan termal, arsitektur vernakular, masjid tuha indrapuri, cfd



Abstract

A mosque is a place of worship for Muslims. The difficulty in achieving thermal comfort in mosque buildings is caused by high air temperatures and low wind speeds. Masjid Tuha Indrapuri is one of the vernacular mosques built between 1607 and 1636 AD. Despite its age of hundreds of years, this mosque is still actively used to this day and has been designated as a cultural heritage site based on Ministerial Decree No. 014/M/1999 under the Ministry of Education and Culture, with the Aceh Cultural Heritage Preservation Office as the overseeing agency. To maintain its existence, research on thermal comfort through natural ventilation systems is important to conduct, so that Masjid Tuha Indrapuri remains a destination for worship for both the local community and tourists. This mosque is located in Pasar Indrapuri Village, Indrapuri District, Aceh Besar Regency, Aceh Province. This study aims to evaluate thermal conditions and analyze the performance of the natural ventilation system. This research uses a quantitative approach by combining field observations, direct measurements of the building's microclimate, user response surveys over 3 days from 10:00 AM to 4:00 PM, and simulations using the Ansys Fluent application to assess ventilation performance. Data from observations, measurements, and questionnaires are integrated to provide a comprehensive evaluation of the thermal performance of the building and its unique ventilation system. The results were compared with the Indonesian National Standard (SNI 03-6572-2001) to assess the effectiveness of the stack effect in maintaining thermal comfort. The research results show that Masjid Tuha Indrapuri has an average effective temperature value of 27.4°C, which means the building generally has a borderline comfortable warm thermal sensation. Users feel that the conditions are adequate for worship activities. The ventilation performance of the Tuha Indrapuri Mosque is in accordance with the principle of applying the stack effect where the temperature difference between T1-T6 is 1.6°C during cloudy weather conditions, and 3.3°C during sunny weather conditions. Based on the simulation, it shows that the wind on the second roof plays an important role in expelling air from the interior compared to the existing closed ventilation condition. Keywords: Natural Ventilation, Thermal Comfort, Vernacular Architecture, Indrapuri Old Mosque, CFD



    SERVICES DESK